Allow new grinding wheels a running-in period of
30 seconds on the tool. Operators and other
personnel are to stay out of the danger zone
during the trial run. Hold the rotating grinding pin
away from the body.
Never halt a grinding wheel by pressing on its
circumference or face.
Tighten the lock nut only enough to hold the
grinding wheel securely in place.
Operators are to be thoroughly instructed on how
to use the grinding tool safely.
Always examine the grinding pins for signs of
damage before you start to work.
Handle grinding pins and other abrasives
carefully. Do not drop. Avoid knocks.
Make sure the pneumatic motor and the tool’s
bearings are kept properly lubricated, particularly
after a long period of use.
When fitting a grinding pin, be sure to leave a gap
of at least 1 cm between the back of the abrasive
and the tool lock nut.
Make sure that the air hose connections and hose
couplings are tight and that the air pressure is the
same as that specified in the instructions.
5. Putting into operation
Screw the supplied plug-in nipple into the air
connection after you have wound 2 to 3 layers of
sealing tape around the thread. Insert adapter sleeve
size Ø 3 or Ø 6 mm depending on which grinding pin
you want to use. To do so, unscrew the lock nut,
insert the adapter sleeve and re-tighten the lock nut
by hand. Then insert the correct grinding pin (make
sure it has the correct shaft diameter!) and tighten
the lock nut with the two chuck keys, using the one
key to hold the adapter sleeve mount.
6. Maintenance and cleaning
Observance of the following maintenance
instructions will ensure that this quality tool gives you
years of troublefree service.
Regular lubrication is vital for the long-term, reliable
operation of your pin grinder. Use only special tool oil
for this purpose.
You can choose from the following options for
lubricating the tool:
6.1 By mist oiler
A complete conditioning unit includes a mist oiler and
is fitted to the compressor.
6.2 By hand
Each time before you use your pin grinder, feed 3-5
drops of special tool oil into the air connection. If the
pneumatic tool has not been used for several days,
you must feed 5-10 drops of oil into the air
connection before you switch on.
Keep your pneumatic tool in dry rooms only.
7. Accessories
Special oil for pneumatic tools 500 ml
Art. No. 41.383.10
8. The warranty does not cover:
Wearing parts
Damage caused by an unacceptable level of
working pressure.
Damage caused by unconditioned compressed
air.
Damage caused by improper use or unauthorized
tampering.
9. Ordering replacement parts
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
Anleitung DSL 250-2_SPK1 13.07.2006 13:15 Uhr Seite 6