9
Points to note when
setting up the
compressor
●
Examine the machine for signs
of transit damage. Report any
damage immediately to the
company which delivered the
compressor.
●
Before you put the compressor
into operation, check the oil
level in the compressor pump.
●
The compressor should be set
up near the working consumer.
●
Avoid long air lines and long
supply lines (extensions).
●
Make sure the intake air is dry
and dust-free.
●
Do not set up the compressor
in damp or wet rooms.
●
The compressor may only be
used in suitable rooms (with
good ventilation and an
ambient temperature from +5°
to +40°C). There must be no
dust, acids, vapors, explosive
gases or inflammable gases in
the room.
●
The compressor is designed to
be used in dry rooms. It is
prohibited to use the
compressor in areas where
work is conducted with sprayed
water.
Safety instructions for
working with
compressed air and
paint sprayers
Important!
Note the pertinent
accident prevent regulations in
force in your area!
Compressors and lines reach
high temperatures during
operation. Avoid contact! Risk of
burns!
Gases or vapours drawn in by the
compressor have to be kept free
of constituents that may cause
fire or explosions inside the
compressor.
When you disconnect the hose
coupling, hold the coupling
element in your hand to prevent
injury from the whiplashing hose.
Wear goggles when working with
the blow-out gun. Injuries may
easily result from foreign bodies
and blasted parts.
Never point the blow-out gun at
other persons and never use it to
clean clothes that are still being
worn.
Note the safety
instructions for paint
spraying!
Important!
Note the pertinent
accident prevent regulations in
force in your area!
●
Never process paints or
solvents with a flash point
below 21°C.
●
Never heat paints or solvents.
●
It is imperative to use filtering
equipment (face masks) when
processing harmful liquids.
Note also the information
concerning safety precautions
published by the manufacturers
of these liquids.
●
Smoking is prohibited during
the spraying operation and in
the work room. Paint vapours
are highly flammable.
●
Make sure there are no open
fires or open lights in the work
room. Sparking machines are
not to be used.
●
Do not keep or consume food
and drink in the work room.
Paint vapours are harmful.
●
The details and designations of
the Ordinance on Hazardous
Substances, which are
displayed on the outer
packaging of the processed
material, must be observed.
Additional protective measures
are to be undertaken if
GB
Read this manual carefully before putting the compressor into operation!
Technical data
Power supply
230 V ~ 50 Hz
Motor rating in kW/h.p.
1,1 / 1,5
Compressor speed in rpm
2850
Operating pressure in bar
8
Pressure vessel volume in litre
24
Theoretical intake rate in l/min.
154
Sound power level LWA in dB(A)
96
Sound pressure level LPA in dB(A)
76
Protection type
IP 20
Machine weight in kg
21
Anleitung Euro 1500-1 SPK1 05.07.2005 8:54 Uhr Seite 9