Once you see the first optional function displayed you may use the up arrow
↑ or down arrow ↓ keys to scroll through all of the available option on the
system. To enter into the calibration procedure, you will be required to
enter an additional code (see CALIBRATION section 8.0).
At any time you may press
ESC
to exit the menu.
9.1 Set Points - Adjusting & General Scheme (if
included)
Enter into the options menu by following the instructions in section 9.
Use the arrow keys ↑↓ to select
SET P
and press
ENTER
.
S/P 1
will be
displayed. Press
ENTER
again and the display will give the current level of
set
point
#1.
Use
the
arrow
keys
to
level.
To scroll more quickly, hold down the arrow key. At first the rightmost digit
will change. Continue holding down the arrow key for faster scrolling. After
a few beeps, the next digit will start to scroll and so on until the leftmost
digit is scrolling.
Once the desired level is reached press
ENTER
. The display will flash OK
and the revert back to
S/P 1
. If the system is equipped with a second set
point, use the arrow keys to select
S/P 2
and follow the same procedure to
set the second set point.
Press
ESC
to exit the set point menu.
General scheme
An example for the connection of set point 1 to a relay:
Vin ≤ 60 V DC, AC @ 0.5 A N.C. 5 pin connector