_NV Ron 2000 4.2

8/37

3/25/2016

LBS
K.NTON (Kilo Newton)
DECA.N (Deca Newton)
N.WTON (Newton)
KG
The current weight value will then be displayed.

Before  loading  the  system,  press

ZERO

until

ZERO

is  displayed.  The  system

should then read

GROSS

then

0

.

Once use of the system has been completed, press the

ON/OFF

key to power

down.  Return both the load cell and indicator to their carrying case or another

appropriate safe place of storage.

When closing the carrying case, please ensure that the cable is not caught in the

edges of the case as this will likely damage the cable.

General operation of the keyboard:

When pressing a key, the system responds with a short audio signal

(a beep) followed by a change to the display. For example, if one

presses the

MAX

key, the

MAX

sign will be displayed. The key

should  be  pressed  continuously  until  the  beep  is  heard  and  visual  sign  appears.

Exceptions are turning the system on or off which does not require a long press.  Also,

when several  keys are  pressed in sequence as part of a code during calibration, the

visual signal will only appear upon completion of the code, but the beep will still follow

each valid key press. If the pass code is not accepted, the display will read

COD.E.R

.

In this case, a new attempt should be made.  (See Calibration for more.)

3. Tare

Switching between Gross and Net modes

T

he system features a Tare function that enables the user to ensure the display

reads 0 even though there may be weight on the system such as from a sling,

shackles or  a  container.  This  capability  makes  the  system  easy  to  use  as  it

eliminates the need for the operator to subtract the weight of the container etc.

when only the net amount of the load is required.



Содержание RON 2000

Страница 1: ...RON 2000 DYNAMOMETER CRANE SCALE Eilon Engineering Weighing Systems Ltd Instruction Manual Version 4 2 Generation 4...

Страница 2: ...N M A N U A L F O R The Ron 2000 Shackle Type Hook Type Eilon Engineering Industrial Weighing Systems Ltd Phone 866 669 6122 Web www eilon engineering com E mail info eilon engineering com Shackles no...

Страница 3: ...9 3 Time setting the real time clock if included 16 9 4 RS 232 Digital Output Communication Data if included 17 9 5 Print Mode Selection only if the system is equipped with the RS 232 output 20 9 6 B...

Страница 4: ...angerous and is therefore STRICTLY PROHIBITED except during the system s annual safety testing This testing must be performed by qualified personnel and allows the system to be overloaded up to 25 of...

Страница 5: ...er becomes familiar with the particular needs of their system the need for calibration may vary Between calibrations the user can verify whether the systems are still calibrated correctly by using a k...

Страница 6: ...ns are observed No amount of safety features and engineering can be a substitute for common sense and a desire to work safely Ron systems are prohibited by the manufacturer and or seller to be used in...

Страница 7: ...ny attempt has been made to open any part of the system by any parties other than those specifically authorized by Eilon Engineering Ltd Batteries are not covered by this warranty The system supplied...

Страница 8: ...ometerbasicinformation The Ron 2000 is available either as a Shackle or Hook Type The system consists of a Load Cell and an indicator R R Ro o on n n 2 2 20 0 00 0 00 0 0 l l lo o oa a ad d d c c ce e...

Страница 9: ...ries rated 3AH will result in at least 2000 hours of battery life more than two months Occasional use will extend the battery life up to several years During use press ENTER to check the current batte...

Страница 10: ...r selectable 21 Wireless communication to additional display or PC 2 Operation Basicoperationof Ronsystemsandhelpfultipsandtricks Before operation be sure the shackles you intend to use are appropriat...

Страница 11: ...MAX key the MAX sign will be displayed The key should be pressed continuously until the beep is heard and visual sign appears Exceptions are turning the system on or off which does not require a long...

Страница 12: ...stem features a MAX aka PEAK HOLD function MAX will store the maximum weight that the system has detected since it was last powered on or since the Gross Net mode was changed Press the MAX key until t...

Страница 13: ...checked by an authorized inspector before being used again Please note that both overload warnings remain functional at the same levels 100 130 of full capacity whether the system is in Gross or Net m...

Страница 14: ...rom low voltage When the system is turn on the batteries energy level is displayed as a percentage e g 100 During use press the ENTER key to check the current battery level Optional Rechargeable Batte...

Страница 15: ...and may result in the batteries exploding If you are using disposable batteries in a system sold with rechargeable ones please remove the charger from the system s carrying case or place of storage i...

Страница 16: ...the best and most accurate results A known weight between 80 100 of capacity may be used but never a weight more than this If the system includes a dampened display averaging the dampening should be...

Страница 17: ...ain from the beginning Once the load value on the display matches that of the known weight currently loaded press ENTER The display will flash WAIT and then OK This means the system has successfully b...

Страница 18: ...ed Press ENTER again and the display will give the current level of set point 1 Use the arrow keys to level To scroll more quickly hold down the arrow key At first the rightmost digit will change Cont...

Страница 19: ...e the arrow keys again and scroll to the desired unit of measurement The available units are Lbs K NTON Kilo Newtons DECA N Deca Newtons N WTON Newtons KG M TON Metric tons S TON Short tons When the d...

Страница 20: ...cation Data if included Possible baud rates 9 600 19 200 38 400 115 200 Length 8 bits Stop bits 1 bit Paring bit none Data output modes The RS 232 output on Ron systems has two modes of data output th...

Страница 21: ...measurement Data 1 7 2 tab space tab 1 3 UNITS Measurement units KG S TON DECA N K NTON LBS LB 10 S TON M TON 2 5 6 6 3 6 5 5 4 tab space tab 1 5 TARE Exclusion of fixed weight Net Gross 3 5 6 tab spa...

Страница 22: ...0 M TON Net DATA 0 000 M TON Net DATA 0 000 M TON Net DATA 0 000 M TON Net DATA 0 315 M TON Gross DATA 0 315 M TON Gross DATA 0 315 M TON Gross DATA 1 015 M TON Gross DATA 1 010 M TON Gross DATA 1 715...

Страница 23: ...tant flow default the displayed valued will be output at a rate of about once per second 2 Continuous upon value change the displayed value will only be output when there is a change in the reading If...

Страница 24: ...y Value and total number of loads D L 1 reading 1 from Data Logger memory D L 2 reading 2 from Data Logger memory D L etc 5 DATE TIME if the system is equipped with the optional real time clock 9 6 Ba...

Страница 25: ...e system will reject it This filter is based on the fact that a load reading of zero must be sensed by the system in between loads If the system does not find a zero value before the current load is e...

Страница 26: ...obtain the load value in the new selected measuring units 9 9 Data Logger standard manual if included The standard data logger D L stores measurements in the indicator s internal memory Memories are...

Страница 27: ...nter C Seeing the total number of D L entries Press DATA L DATA L will appear on the screen Then press TARE The display will read DL N and then show the total number of readings currently stored in th...

Страница 28: ...hat affect the weight value stored MAX MIN AVERAGE MAX The maximum value registered by the system during each time interval will be logged in the memory To begin logging the user must switch from ADL...

Страница 29: ...ser to select the time interval T by selecting Days up to 31 and or Hours up to 24 and or Minutes up to 60 and or Seconds up to 60 Once the selection is completed press ESC to exit and return to the o...

Страница 30: ...of four wire rope falls the system will multiply the sensed load by four and display the result The system will multiply the sensed load by any number selected by the user to suit the actual reeving a...

Страница 31: ...alculates the average load based on the measurements taken over a given number of seconds here called T When measuring begins the first reading will show after about one second After two seconds the d...

Страница 32: ..._NV Ron 2000 4 2 29 37 3 25 2016 E RS 232 0 1V A V B GND for 0 1V C RS 232 D GND for RS 232 E RS 485 A NO B NO C A RS 485 D A RS 485 E GND...

Страница 33: ...then try turning it off If it does not switch off it can still be used until you have an opportunity to send it to an authorized service center With full batteries the system will function for more th...

Страница 34: ...and held indicator b The system should be checked in an authorized service lab 6 The system switches itself off a Check the batteries see battery care section b Try to operate the system without the e...

Страница 35: ...econds and Reset Data Logger S 011 Eeprom failure E 015 Active Real time Clock RTC power Check Replace battery 020 RS232 or SetPoint still active wait several seconds and try again S 25 26 Eeprom ON O...

Страница 36: ...ds size cap in short tons model G209A 1 3 8 31 3 M650A 2 3 8 31 3 M650A 3 31 3 M650A 5 5 8 3 4 7 M652A 10 1 11 8 15 M655A 12 1 11 8 15 M655A 15 11 8 11 4 18 M656A 20 13 8 G 2140 G 5263 25 11 2 11 2 30...

Страница 37: ...6 20 23 25 indicator 3 5 6 7 8 9 11 12 17 18 21 23 24 25 30 31 keyboard 3 6 8 29 laboratory 2 13 30 load cell 2 3 5 7 8 24 26 27 29 max 6 8 9 13 14 20 21 22 24 25 31 overload 4 10 27 plug 7 print 14 1...