46
Contents
1
Operation and functional characteristics ........................................................................................... 47
1.1
Door terminal and terminal module 48
1.2
Overview of operating displays
49
1.3
Monitoring and alarm functions
50
1.3.1
Actuating the emergency button
50
1.3.2
Door open monitoring
50
1.3.3
Locked status monitoring function
50
1.3.4
Door sabotage
50
1.3.5
Sabotage at the door terminal, terminal module or control unit 50
1.3.6
Sabotage to cables
50
1.4
Switching functions
51
1.4.1
Temporary release
51
Permanent unlocking
51
1.4.3
Locking 51
1.4.4
Alarm reset
51
1.5
Function variants 53
1.5.1
Temporary release
53
1.5.2
Permanent unlocking
53
1.5.3
Pre-alarm
53
1.5.4
Alarm
53
1.5.5
Alarm time
53
1.6
Special function I: Systems with indirect release. The Emergency Exit Control Unit 720-32 54
1.7
Special functions II: Operation of the emergency exit control unit using electrical security lock 809 55
1.8
Special function III: Operation at the effeff door control bus with control panel 925
56
1.9
Determination of an alarm condition 57
1.10
Eliminating the reasons for the alarm
58
2
Installation ............................................................................................................................................. 59
2.1
Mounting the control unit
60
2.2
General information on the electrical installation
61
2.3
Cable diagrams and connection details
62
2.3.1
Emergency exit security system for a single-leaf door (cable diagram)
62
2.3.2
Emergency exit security system for a two-leaf emergency exit (cable diagram)
63
2.3.3
Mains and battery connection
64
2.4
Locking systems with the door terminal 1337-10/11
66
2.4.1
Connection detail parallel connection control unit 1332 and door terminal 1337-10/11
66
2.4.2
Connection detail: Parallel connection of two door terminals 1337-10/11 67
2.4.3
Overall terminal diagram 720-30 with door terminal 1337-10/1168
2.5
Locking systems with terminal module 1370-10
70
2.5.1
Connection detail: Terminal module 1370-10 with operator terminal 1332
70
2.5.2
Connection detail parallel connection of two terminal modules 1370-10 71
2.5.3
Overall terminal diagram 720-30 with terminal module 1370-10 72
2.6
Systems with indirect (central) release (special function I)
74
2.6.1
Terminal diagram, indirect (central) release 75
2.6.2
Overall terminal diagram 720-32
76
2.7
Setting switches for functions and time sequences
78
2.7.1
Default positions of setting switches78
2.7.2
Time inputs
79
2.7.3
S 5 function variants
79
2.7.4
S 6 Bus address 80
2.7.5
S 7 Special functions
80
2.8
Control inputs
81
2.9
Signal outputs
81
2.10
Connection of fire alarm systems (terminals 45-46)
82
2.11
Special function II: Operation of the emergency exit control unit with the electrical security lock 809 83
2.12
Special function III Operation of the control system at control panel 925 (bus technology) 84
2.13
Specifications
85
3
Commissioning, maintenance, recurring tests .................................................................................. 86
3.1
Commissioning and recurring tests 86
3.2
Maintenance
86
4
Checklist for testing prior to initial commissioning .......................................................................... 87