operate at a distance up to 6 m. For longer distances, an interface circuit external to the
pump can be necessary.
The software in the pump can operate with the other pumps connected to a single serial
link master. This is a multi-drop mode. The RS485 option is recommended for the multi-
drop mode. When the RS232 option is selected, more hardware is necessary to link
number of pump units to a single serial link master. A concept drawing of one possible
arrangement is shown in
Figure: Conceptual diagram for multi-drop connection using
. When the RS485 option is selected, it is easy to connect number of
pumps to a single master. Refer to
Figure: RS485 multi-drop connection
Figure 21 Motor controller status information
1. Normal LED
2. Status LED
3. Alarm LED
4. Accessory connector
5. Serial receive LED
6. Serial transmit LED
7. Standby speed increase button
8. RS232 / RS485 slide switch
9. USB connector
10. Standby speed decrease button
1. Normal LED
2. Status LED
3. Alarm LED
4. Accessory connector
5. Serial receive LED
6. Serial transmit LED
7. Standby speed increase button
8. RS232 / RS485 slide switch
9. USB connector
10. Standby speed decrease button