INSTALLATION
CHIMNEY
STACK
CHIMNEY
STACK
INSULATE THE
SMOKE VENT
CONTAINER
FOR SOOT
INSPECTION-
ABLE
ROOF VENT WITH STEEL CHIMNEY FLUE
In installation of the chimney
fl
ue, always guar-
antee an inspection door to enable periodic
cleaning of soot and a condensate collector
with drainage to evacuate any condensate.
If the smoke pipe is installed completely exter-
nally, you should make it fully in stainless steel
with a double wall to guarantee better resist-
ance to atmospheric agents and adequate
temperature of the smoke vent.
ROOF VENT WITH TRADITIONAL CHIMNEY
FLUE
Combustion gas can also be evacuated using
an existing, traditional chimney
fl
ue provided it
is built to standard.
It must comply with the following regulations:
• it must be equipped with adequate insulation
in the exposed external section;
• the internal section must be constant;
• it must be created using material resistant to
high temperatures, the action of combustion
products and any condensate that could form;
• it must have a soot and condensate collection
chamber which can be inspected via a door.
• the smoke channel (section of piping that con-
nects the boiler to the chimney
fl
ue) can have:
- maximum 3 bends
- maximum 2 metres horizontally
CONTAINER
FOR SOOT
WITH DRAIN-
AGE
FOR CONDEN-
SATE
Содержание LAGUNA M 25
Страница 37: ...37 ITALIANO POSIZIONE DISPOSITIVI SICUREZZA Posizione termostato sicurezza a riarmo manuale ISTRUZIONI D USO...
Страница 82: ...82 ENGLISH SAFETY DEVICES POSITIONING Position of manual reset safety thermostat INSTRUCTIONS FOR USE...
Страница 127: ...127 FRAN AIS POSITIONNEMENT DES DISPOSITIFS DE S CURIT Position thermostat s curit au r armement manuel MODE D EMPLOI...
Страница 272: ...272 cod 941249 02 16 E w w w e d i l k a m i n c o m...