C
HAPTER
42
| CFM Commands
Cross Check Operations
– 1374 –
mep-unknown
–
Sends a trap if an unconfigured MEP comes up.
D
EFAULT
S
ETTING
All continuity checks are enabled.
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
◆
For this trap type to function, cross-checking must be enabled on the
required maintenance associations using the
command.
◆
A mep-missing trap is sent if cross-checking is enabled (with the
command), and no CCM is received for a
remote MEP configured in the static list (with the
command).
◆
A mep-unknown trap is sent if cross-checking is enabled, and a CCM is
received from a remote MEP that is not configured in the static list.
◆
A ma-up trap is sent if cross-checking is enabled, and a CCM is received
from all remote MEPs configured in the static list for this maintenance
association.
E
XAMPLE
This example enables SNMP traps for mep-unknown events detected in
cross-check operations.
Console(config)#snmp-server enable traps ethernet cfm crosscheck mep-unknown
Console(config)#
mep crosscheck
mpid
This command statically defines a remote MEP in a maintenance
association. Use the
no
form to remove a remote MEP.
S
YNTAX
[
no
]
mep crosscheck mpid
mpid
ma
ma-name
mpid –
Identifier for a maintenance end point which exists on
another CFM-enabled device within the same MA. (Range: 1-8191)
ma-name –
Maintenance association name. (Range: 1-43
alphanumeric characters)
D
EFAULT
S
ETTING
No remote MEPs are configured.
C
OMMAND
M
ODE
CFM Domain Configuration
Содержание ECS4110-28T
Страница 1: ...Management Guide www edge core com ECS4110 28T 28P 52T 52P 28 52 Port Gigabit Ethernet Layer 2 Switch...
Страница 2: ......
Страница 4: ......
Страница 63: ...FIGURES 63 Figure 428 Configuring VLAN Translation 1177...
Страница 64: ...FIGURES 64...
Страница 72: ...TABLES 72...
Страница 74: ...SECTION I Getting Started 74...
Страница 102: ...SECTION II Web Configuration 102 General IP Routing on page 679...
Страница 154: ...CHAPTER 4 Basic Management Tasks Resetting the System 154...
Страница 198: ...CHAPTER 5 Interface Configuration VLAN Trunking 198 Figure 65 Configuring VLAN Trunking...
Страница 272: ...CHAPTER 9 Congestion Control Automatic Traffic Control 272...
Страница 286: ...CHAPTER 10 Class of Service Layer 3 4 Priority Settings 286...
Страница 420: ...CHAPTER 13 Security Measures DHCP Snooping 420...
Страница 566: ...CHAPTER 14 Basic Administration Protocols OAM Configuration 566...
Страница 638: ...CHAPTER 15 Multicast Filtering Multicast VLAN Registration for IPv6 638...
Страница 662: ...CHAPTER 16 IP Configuration Setting the Switch s IP Address IP Version 6 662...
Страница 678: ...CHAPTER 17 IP Services Configuring the PPPoE Intermediate Agent 678...
Страница 792: ...CHAPTER 21 System Management Commands Switch Clustering 792...
Страница 822: ...CHAPTER 23 Remote Monitoring Commands 822...
Страница 888: ...CHAPTER 24 Authentication Commands PPPoE Intermediate Agent 888...
Страница 968: ...CHAPTER 25 General Security Measures Port based Traffic Segmentation 968...
Страница 994: ...CHAPTER 26 Access Control Lists ACL Information 994...
Страница 1034: ...CHAPTER 28 Link Aggregation Commands Trunk Status Display Commands 1034...
Страница 1044: ...CHAPTER 29 Power over Ethernet Commands 1044...
Страница 1084: ...CHAPTER 33 UniDirectional Link Detection Commands 1084...
Страница 1090: ...CHAPTER 34 Address Table Commands 1090...
Страница 1194: ...CHAPTER 37 VLAN Commands Configuring Voice VLANs 1194...
Страница 1388: ...CHAPTER 42 CFM Commands Delay Measure Operations 1388...
Страница 1410: ...CHAPTER 44 Domain Name Service Commands 1410...
Страница 1420: ...CHAPTER 45 DHCP Commands DHCP Relay 1420...
Страница 1472: ...CHAPTER 46 IP Routing Commands IPv4 Commands 1472...
Страница 1474: ...SECTION IV Appendices 1474...
Страница 1502: ...COMMAND LIST 1502...
Страница 1513: ......
Страница 1514: ...ECS4110 28T ECS4110 28P ECS4110 52T ECS4110 52P E072014 ST R02 150200000929A...