C
HAPTER
42
| CFM Commands
Defining CFM Structures
– 1365 –
show ethernet cfm
maintenance-points
remote detail
This command displays detailed CFM information about a remote MEP in
the continuity check database.
S
YNTAX
show ethernet cfm maintenance-points remote detail
{
mac
mac-address
|
mpid
mpid
}
[
domain
domain-name
|
level
level-id
|
ma
ma-name
]
mac-address
– MAC address of a remote maintenance point.
This address can be entered in either of the following formats: xx-
xx-xx-xx-xx-xx or xxxxxxxxxxxx
mpid –
Maintenance end point identifier. (Range: 1-8191)
domain-name –
Domain name. (Range: 1-43 alphanumeric
characters)
level-id
– Authorized maintenance level for this domain.
(Range: 0-7)
Table 193: show ethernet cfm maintenance-points local detail mep
- display
Field
Description
MPID
MEP identifier
MD Name
The maintenance domain for this entry.
MA Name
Maintenance association to which this remote MEP belongs
MA Name Format
The format of the Maintenance Association name, including
Character String or ICC Based
Level
Maintenance level of the local maintenance point
Direction
The direction in which the MEP faces on the Bridge port (up or down).
Interface
The port to which this MEP is attached.
CC Status
Shows if the MEP will generate CCM messages.
MAC Address
MAC address of the local maintenance point. (If a CCM for the
specified remote MEP has never been received or the local MEP
record times out, the address will be set to the initial value of all Fs.)
Defect Condition
Shows the defect detected on the MEP.
Received RDI
Receive status of remote defect indication (RDI) messages on the
MEP.
AIS Status
Shows if MEPs within the specified MA are enabled to send frames
with AIS information following detection of defect conditions.
AIS Period
The interval at which AIS information is sent.
AIS Transmit Level
The maintenance level at which AIS information will be sent for the
specified MEP.
Suppress Alarm
Shows if the specified MEP is configured to suppress sending frames
containing AIS information following the detection of defect
conditions.
Suppressing Alarms
Shows if the specified MEP is currently suppressing sending frames
containing AIS information following the detection of defect
conditions.
Содержание ECS4110-28T
Страница 1: ...Management Guide www edge core com ECS4110 28T 28P 52T 52P 28 52 Port Gigabit Ethernet Layer 2 Switch...
Страница 2: ......
Страница 4: ......
Страница 63: ...FIGURES 63 Figure 428 Configuring VLAN Translation 1177...
Страница 64: ...FIGURES 64...
Страница 72: ...TABLES 72...
Страница 74: ...SECTION I Getting Started 74...
Страница 102: ...SECTION II Web Configuration 102 General IP Routing on page 679...
Страница 154: ...CHAPTER 4 Basic Management Tasks Resetting the System 154...
Страница 198: ...CHAPTER 5 Interface Configuration VLAN Trunking 198 Figure 65 Configuring VLAN Trunking...
Страница 272: ...CHAPTER 9 Congestion Control Automatic Traffic Control 272...
Страница 286: ...CHAPTER 10 Class of Service Layer 3 4 Priority Settings 286...
Страница 420: ...CHAPTER 13 Security Measures DHCP Snooping 420...
Страница 566: ...CHAPTER 14 Basic Administration Protocols OAM Configuration 566...
Страница 638: ...CHAPTER 15 Multicast Filtering Multicast VLAN Registration for IPv6 638...
Страница 662: ...CHAPTER 16 IP Configuration Setting the Switch s IP Address IP Version 6 662...
Страница 678: ...CHAPTER 17 IP Services Configuring the PPPoE Intermediate Agent 678...
Страница 792: ...CHAPTER 21 System Management Commands Switch Clustering 792...
Страница 822: ...CHAPTER 23 Remote Monitoring Commands 822...
Страница 888: ...CHAPTER 24 Authentication Commands PPPoE Intermediate Agent 888...
Страница 968: ...CHAPTER 25 General Security Measures Port based Traffic Segmentation 968...
Страница 994: ...CHAPTER 26 Access Control Lists ACL Information 994...
Страница 1034: ...CHAPTER 28 Link Aggregation Commands Trunk Status Display Commands 1034...
Страница 1044: ...CHAPTER 29 Power over Ethernet Commands 1044...
Страница 1084: ...CHAPTER 33 UniDirectional Link Detection Commands 1084...
Страница 1090: ...CHAPTER 34 Address Table Commands 1090...
Страница 1194: ...CHAPTER 37 VLAN Commands Configuring Voice VLANs 1194...
Страница 1388: ...CHAPTER 42 CFM Commands Delay Measure Operations 1388...
Страница 1410: ...CHAPTER 44 Domain Name Service Commands 1410...
Страница 1420: ...CHAPTER 45 DHCP Commands DHCP Relay 1420...
Страница 1472: ...CHAPTER 46 IP Routing Commands IPv4 Commands 1472...
Страница 1474: ...SECTION IV Appendices 1474...
Страница 1502: ...COMMAND LIST 1502...
Страница 1513: ......
Страница 1514: ...ECS4110 28T ECS4110 28P ECS4110 52T ECS4110 52P E072014 ST R02 150200000929A...