OPERATING INSTRUCTIONS

Initial Lighting

Upon completing the gas line or turning the gas valve on after it 

has been in the “OFF” position, a small amount of air will be in the 

lines. When first lighting the fireplace, it will take a few minutes 

for the lines to purge themselves of this air. Once the purging is 

complete, the fireplace will light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging 

if the gas valve is not turned to “OFF.”

Pilot Flame (Figure 21)

The  thermopile/thermocouple  (standing  pilot)  tips  should  be 

covered with flame. 

Figure 21

750 Millivolt System

The standing pilot (750 millivolt system) is a continuous burning 

pilot. The pilot remains ON even when the main burner is OFF.
When  you  ignite  the  pilot,  the  thermopile  produces  millivolts 

(electrical current) which energizes the magnet in the gas valve. 

After 30 seconds to 1 minute time period you can release the gas 

control knob and the pilot will stay ON. Allow your pilot flame to 

operate an additional one (1) to two (2) minutes before you turn the 

gas control knob from the PILOT position to the ON position. This 

time period allows the millivolts (electrical current) to build-up to 

a sufficient level allowing the gas control to operate properly.
1.  Follow  the  SAFETY  and  LIGHTING  INSTRUCTIONS  for 

standing pilot controls found in this manual and on labels found 

in control compartment behind the door assembly.

CAUTION: During the initial purging and subsequent lightings, 

never allow the gas valve control knob to remain depressed in 

the “pilot” position without pushing the piezo ignitor button 

at least once every second. 

2.  During the operating season, leave the control valve knob in the 

“ON” position. This will allow the pilot flame to remain lit. Turn 

the burner flame on or off with the fireplace REMOTE/OFF/ON 

switch, wall switch or remote controls.

NOTE:

 The gas control valve allows you to increase or decrease the 

height of the main burner flame. The control valve has a pressure 

regulator with a knob as shown in 

Figure 20

. Rotate the knob 

clockwise to “HI” to increase the flame height and counterclockwise 

to “LO” to decrease the flame height.
3.  When the operating season is over, turn the REMOTE/OFF/ON 

switch to “OFF” and the control valve to “OFF”. The system, 

including the pilot light, will be shut down.

Figure 20

The OWNER  should carefully read and follow these operating 

instructions at all times. Lower the door assembly to view the gas 

controls for the fireplace.  

Содержание DV25IN33L-1

Страница 1: ...iance is not convertible for use with other gases unless a certi ed kit is used GAS FIRED Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store...

Страница 2: ...10 12 Vertical Termination 13 Alternate ON OFF Switch Installation 14 Surround Panel Installation 15 Blower Accessory Information 16 Log Placement 17 Operating Instructions 18 Standing Pilot Lighting...

Страница 3: ...t clean Vent cap is hot while replace is in operation Installation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected before use and at least annually by a quali...

Страница 4: ...perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wal...

Страница 5: ...ng jurisdiction State of Massachusetts The installation must be made by a licensed plumber or gas tter in the Commonwealth of Massachusetts The installation must conform with local codes or in the abs...

Страница 6: ...talling to an existing round replace chimney pipe DVVK3FV Vertical Vent Kit 25 Two pieces of 25 FlexVent Rectangle Cap Flashing connectors and clamps Recommended when installing to a square or rectang...

Страница 7: ...28 14 1 2 11 1 8 25 1 4 12 3 4 17 18 5 16 27 6 3 4 9 20 25 5 8 40 DV33IN 22 3 4 31 16 14 1 8 28 1 4 14 1 4 18 3 4 21 5 16 30 8 1 4 10 1 2 21 1 2 28 5 8 43 DV35IN 24 3 4 34 16 16 1 8 31 1 4 14 1 4 21 3...

Страница 8: ...10 1 3 4 23 11 Combustible Material No greeting cards stockings or ornamentation of any type should be placed on or attached to the replace The ow of heat can ignite combustibles Figure 4 8 MINIMUM CL...

Страница 9: ...s results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the replace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural gas valves have a buil...

Страница 10: ...sting air circulation vents or grills NOTE Cutting of sheet metal parts of a replace in order to install the replace insert is prohibited WARNING Only the surround as supplied may be used to cover int...

Страница 11: ...asonry chimney may need to be removed to allow installation of the exible vent pipe When installing into a zero clearance factory built wood burning replaces the use of the DVKI Round Vertical Termina...

Страница 12: ...NT CONNECTION RETAINER SCREWS MAY BE INSTALLED THROUGH THE VENT CLAMPS TO ENSURE POSITIVE SECUREMENT OF VENTING SCREWS ADDED THROUGH VENT CLAMPS TO RETAIN VENTING TO COLLARS RECOMMENDED USE HIGH TEMP...

Страница 13: ...ly dripping out at joints or seams Condensate can cause corrosion of caps pipe and ttings It may be caused by having excessive lateral runs or having exterior portions of the system exposed to cold we...

Страница 14: ...ound panel assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides Lift the surround panel assembly slightly until the bottom return ange top pa...

Страница 15: ...FINISHING THE FIREPLACE INSERT NEVER OBSTRUCT OR MODIFY THE AIR INLET OUTLET LOUVERS ON THE FIREPLACE IN SERT IN ANY MANNER NOTE INSTALL SURROUND PANELS SO THAT THE TOP PANEL RETURN FLANGE SLIDE S OV...

Страница 16: ...nd BTU input level setting control by adjustment of the HI LO knob located on the gas valve Blower removal instructions Servicing or removal of the blower system must be performed by a quali ed servic...

Страница 17: ...support Note DV25IN models incorporate two small tabs in the rear log support that keep the back log positioned correctly DV33IN models have one small tab in the rear log support to ensure the back lo...

Страница 18: ...N position This time period allows the millivolts electrical current to build up to a suf cient level allowing the gas control to operate properly 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for sta...

Страница 19: ...switch to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a re or explosion may result causing property damage personal injury or loss of l...

Страница 20: ...ptional Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8m or less length of 18 A W G minimum wire and connect it to the replace valve pigtails WARNIN...

Страница 21: ...s from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading atTH TP TPterminals...

Страница 22: ...that no debris is interfering with the ow of air Inspect entire vent system for proper function Cleaning Logs Use a soft brush attachment on a vacuum cleaner to gently remove dust or soot deposits fr...

Страница 23: ...what your dealer can furnish contact Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finish Hammered Pewt...

Страница 24: ...23015 6 0408 Page 24 INSERT PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 39 40 41 7 12 32 42 43 18 44 45 46 48 47 49...

Страница 25: ...23a P286 P270 P244 ORIFICE MAIN BURNER NAT 23b P214 P210 P245 ORIFICE MAIN BURNER LP 24 23311 23017 23017 BURNER ASSEMBLY 25 22959 22959 22959 VALVE BRACKET 26 22739 22738 22738 TUBING ASSEMBLY 27 22...

Страница 26: ...ne the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Number Part Description Fir...

Страница 27: ...23015 6 0408 Page 27 SERVICE NOTES...

Страница 28: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: