background image

23015-6-0408

Page 25

INSERT PARTS LIST

 

PART NUMBER

 INDEX NO.  DV25IN33L(N,P)  DV33IN33L(N,P) 

DV35IN33L(N,P)  DESCRIPTION

 

22950 

22950 

22950 

GUIDE, FLUE CONNECTOR

 

23309 

23211 

23211 

VENT SLIDE PLATE ASSEMBLY

 

R9188 

R9188 

R9188 

GASKET, TOP

 

R9192 

R9196 

R9199 

BRICK PANEL, BACK

 

R9195 

R9198 

R9201 

BRICK PANEL, RIGHT

 

R9194 

R9197 

R9200 

BRICK PANEL, LEFT

 

20448 

20448 

20448 

BRICK LINER BRACKET

 

22951 

22972 

22972 

FIREBOX BAFFLE

 

22958 

22976 

22990 

LOG SHELF

 

10 

23303 

23006 

23320 

GLASS DOOR & FRAME ASSEMBLY

 

11 

23329 

17169 

17127 

LOUVER ASSEMBLY 

 

12 

23158 

23160 

23160 

LOG SUPPORT, FRONT

 

13 

23315 

23024 

23024 

GRATE TANG / BRACKET ASSEMBLY

 

14 

R3435 

R3435 

R3435 

WIRE ASSEMBLY

 

15 

R3436 

R3436 

R3436 

SWITCH, REMOTE/OFF/ON

 

16 

R2708 

R2708 

R2708 

IGNITER, PIEZO

 

17 

23159 

23161 

23504 

LOG SUPPORT, REAR

 

18 

23521 

23521 

23521 

FLAME SHIELD, RIGHT

 

19a 

R7612 

R7612 

R7612 

PILOT ASSEMBLY, SIT (NAT)

 

19b 

R7611 

R7611 

R7611 

PILOT ASSEMBLY, SIT (LP)

 

20 

R9189 

R9189 

R9189 

GASKET, PILOT

 

21 

R5676 

R5676 

R5676 

AIR SHUTTER

 

22 

P253 

P253 

P253 

FITTING, ORIFICE ANGLED 

 

23a 

P286 

P270 

P244 

ORIFICE, MAIN BURNER (NAT)

 

23b 

P214 

P210 

P245 

ORIFICE, MAIN BURNER (LP)

 

24 

23311 

23017 

23017 

BURNER ASSEMBLY

 

25 

22959 

22959 

22959 

VALVE BRACKET

 

26 

22739 

22738 

22738 

TUBING ASSEMBLY

 

27 

22973 

22973 

22973 

SHIELD, VALVE

 

28a 

R7577 

R7577 

R7577 

VALVE, SIT GAS (NAT)

 

28b 

R7578 

R7578 

R7578 

VALVE, SIT GAS (LP)

 

29 

22953 

22953 

22953 

PIEZO BRACKET

 

30 

16223 

16223 

16223 

SPRING RETAINER ASSEMBLY

 

31 

N/A 

23690 

23690 

FLAME SHIELD, LEFT

 

32 

M163 

M163 

M163 

GASKET, FLUE CONNECTOR

 

33 

23009 

23009 

23009 

FLUE CONNECTOR ASSEMBLY

 

34 

R9257 

R9219 

R9219 

LOG, RIGHT FRONT

 

35 

R9258 

R9220 

R9220 

LOG, RIGHT CENTER

 

36 

R9260 

R9252 

R9252 

TWIG, RIGHT

 

37 

R9261 

R9253 

R9253 

TWIG, LEFT

 

38 

R9255 

R9217 

R9217 

LOG, BACK

 

39 

R9259 

R9251 

R9251 

LOG, LEFT CENTER

 

40 

R9256 

R9218 

R9218 

LOG, LEFT FRONT

 

41 

R9268 

R9268 

R9268 

WIRE ASSEMBLY - SWITCH

 

42 

R2522 

R2522 

R2522 

SWITCH, ON / OFF

 

43 

18879 

18879 

18879 

RHEOSTAT ASSEMBLY (SPEED CONTROL)

 

44 

R7649 

R7649 

R7649 

CONTROL, FAN

 

45 

R9211 

R9211 

R9211 

BLOWER ASSEMBLY (MOTOR W/HOUSING)

 

46 

22954 

22954 

22954 

BRACKET, BLOWER

 

47 

R2204 

R2204 

R2204 

CORD SET

 

48 

R7591 

R7591 

R7591 

FLEXLINE W/SHUTOFF VALVE

 

49 

R9644 

R9644 

R9644 

VIBRATION PAD

 USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Содержание DV25IN33L-1

Страница 1: ...iance is not convertible for use with other gases unless a certi ed kit is used GAS FIRED Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store...

Страница 2: ...10 12 Vertical Termination 13 Alternate ON OFF Switch Installation 14 Surround Panel Installation 15 Blower Accessory Information 16 Log Placement 17 Operating Instructions 18 Standing Pilot Lighting...

Страница 3: ...t clean Vent cap is hot while replace is in operation Installation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected before use and at least annually by a quali...

Страница 4: ...perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wal...

Страница 5: ...ng jurisdiction State of Massachusetts The installation must be made by a licensed plumber or gas tter in the Commonwealth of Massachusetts The installation must conform with local codes or in the abs...

Страница 6: ...talling to an existing round replace chimney pipe DVVK3FV Vertical Vent Kit 25 Two pieces of 25 FlexVent Rectangle Cap Flashing connectors and clamps Recommended when installing to a square or rectang...

Страница 7: ...28 14 1 2 11 1 8 25 1 4 12 3 4 17 18 5 16 27 6 3 4 9 20 25 5 8 40 DV33IN 22 3 4 31 16 14 1 8 28 1 4 14 1 4 18 3 4 21 5 16 30 8 1 4 10 1 2 21 1 2 28 5 8 43 DV35IN 24 3 4 34 16 16 1 8 31 1 4 14 1 4 21 3...

Страница 8: ...10 1 3 4 23 11 Combustible Material No greeting cards stockings or ornamentation of any type should be placed on or attached to the replace The ow of heat can ignite combustibles Figure 4 8 MINIMUM CL...

Страница 9: ...s results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the replace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural gas valves have a buil...

Страница 10: ...sting air circulation vents or grills NOTE Cutting of sheet metal parts of a replace in order to install the replace insert is prohibited WARNING Only the surround as supplied may be used to cover int...

Страница 11: ...asonry chimney may need to be removed to allow installation of the exible vent pipe When installing into a zero clearance factory built wood burning replaces the use of the DVKI Round Vertical Termina...

Страница 12: ...NT CONNECTION RETAINER SCREWS MAY BE INSTALLED THROUGH THE VENT CLAMPS TO ENSURE POSITIVE SECUREMENT OF VENTING SCREWS ADDED THROUGH VENT CLAMPS TO RETAIN VENTING TO COLLARS RECOMMENDED USE HIGH TEMP...

Страница 13: ...ly dripping out at joints or seams Condensate can cause corrosion of caps pipe and ttings It may be caused by having excessive lateral runs or having exterior portions of the system exposed to cold we...

Страница 14: ...ound panel assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides Lift the surround panel assembly slightly until the bottom return ange top pa...

Страница 15: ...FINISHING THE FIREPLACE INSERT NEVER OBSTRUCT OR MODIFY THE AIR INLET OUTLET LOUVERS ON THE FIREPLACE IN SERT IN ANY MANNER NOTE INSTALL SURROUND PANELS SO THAT THE TOP PANEL RETURN FLANGE SLIDE S OV...

Страница 16: ...nd BTU input level setting control by adjustment of the HI LO knob located on the gas valve Blower removal instructions Servicing or removal of the blower system must be performed by a quali ed servic...

Страница 17: ...support Note DV25IN models incorporate two small tabs in the rear log support that keep the back log positioned correctly DV33IN models have one small tab in the rear log support to ensure the back lo...

Страница 18: ...N position This time period allows the millivolts electrical current to build up to a suf cient level allowing the gas control to operate properly 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for sta...

Страница 19: ...switch to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a re or explosion may result causing property damage personal injury or loss of l...

Страница 20: ...ptional Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8m or less length of 18 A W G minimum wire and connect it to the replace valve pigtails WARNIN...

Страница 21: ...s from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading atTH TP TPterminals...

Страница 22: ...that no debris is interfering with the ow of air Inspect entire vent system for proper function Cleaning Logs Use a soft brush attachment on a vacuum cleaner to gently remove dust or soot deposits fr...

Страница 23: ...what your dealer can furnish contact Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finish Hammered Pewt...

Страница 24: ...23015 6 0408 Page 24 INSERT PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 39 40 41 7 12 32 42 43 18 44 45 46 48 47 49...

Страница 25: ...23a P286 P270 P244 ORIFICE MAIN BURNER NAT 23b P214 P210 P245 ORIFICE MAIN BURNER LP 24 23311 23017 23017 BURNER ASSEMBLY 25 22959 22959 22959 VALVE BRACKET 26 22739 22738 22738 TUBING ASSEMBLY 27 22...

Страница 26: ...ne the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Number Part Description Fir...

Страница 27: ...23015 6 0408 Page 27 SERVICE NOTES...

Страница 28: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: