background image

23015-6-0408

Page 17

LOG PLACEMENT

BACK

LOG

LEFT

TWIG

RIGHT

TWIG

RIGHT

CENTER

LOG

RIGHT FRONT

LOG

LEFT FRONT

LOG

LEFT

CENTER

LOG

Figure 18

Figure 19

Note:

 Center the front two logs on the front log support ledge. Then make 

sure they are positioned all the way forward and touching the back edges 

of the grate tang uprights. The bottom of the two front logs are flat and 

must sit on top of the front log support ledge.

Before you begin: This fireplace insert is supplied with a set of seven ce-

ramic fiber logs. Do not handle these logs with your bare hands. Always 

wear gloves to prevent skin irritation from ceramic fibers. After handling 

logs, wash your hands gently with soap and water to remove any traces 

of fiber.
The  positioning  of  logs  is  critical  to  safe  and  clean  operation  of  this 

fireplace.  Sooting  and  other  problems  may  result  if  the  logs  are  not 

properly and firmly positioned in the fireplace. Refer to 

Figure 18

 and  

Figure  19 

and  corresponding WARNING  when  completing  following 

log placement steps.
1.  Remove top louver, grasp louver, lift and pull forward.

2.  Lower bottom louver, lift and hinge forward.

3.  Release two glass frame spring clamps at bottom of the glass door 

assembly.

4.  Swing the bottom of the glass door outward approximately 10-15 

degrees, then grasping the edges, gently lift upward to remove the 

door assembly, and set aside.

5.  Remove the foam packaging that contains the log set from inside the 

firebox.

6.  Carefully  unpack  the  logs  and  twigs.  Spread  them  out  for  easy 

identification.

7.  Begin with the front left and front right logs. Place these so that 

they are centered left to right on the front log support ledge. The flat 

bottoms will rest on top of the front log support ledge, and they must 

be position all the way forward and touching the back of the grate 

tangs. Important: The front right log has a small knot as shown in 

Figure 18.  

8.  Next install the large rear log. It will be centered left to right and 

placed all the way to the back of the firebox, on top of the rear log 

support. Note: DV25IN models incorporate two small tabs in the 

rear log support that keep the back log positioned correctly. DV33IN 

models have one small tab in the rear log support to ensure the back 

log is in the correct position.  The DV35IN models will have two 

tabs bent forward in the rear log support to ensure proper left to right 

positioning of the log, plus one small tab near the center that keeps 

the back log from shifting forward.

9.  Locate the center left log. It will have two locator pin holes on the 

bottom flat surface. Align the two holes with the two left pins on 

the burner assembly. Make sure this log is not raised up off of the 

burner. The flat bottom surface must be completely resting flat on 

the top of the burner surface.

10.  Install the center right log. It will also have two locator pin holes on 

the bottom flat surface. Align these two holes with the two right pins 

on the burner assembly.  Make sure this log is not raised up off of 

the burner.  The flat bottom surface must be completely resting flat 

on the top of the burner surface.

11.  Add the right twig by placing the locator pin hole on the bottom of 

the twig with the pin on top of the center right log.  The tip of the 

right twig will rest on top of the rear log near the right end.

12.  Add the left twig by placing the locator pin hole on the bottom of 

the twig with the pin on top of the center left log.  The long branch 

of the left twig will rest in a small groove on top of the rear log. This 

groove is near the left end of the rear log.

Warning: Failure to position the parts in accordance with this dia-

gram or failure to use only parts specifically approved with this 

appliance may result in property damage or personal injury.

13.  Replace the glass door assembly onto the fireplace insert.

14.  Secure the glass door with the two spring clamps located under the 

firebox.

15.  Re-install the upper and lower louver assemblies by aligning the end 

tabs with the slots provided in the outer face flanges of the insert.

Note:

  Decorative  Rock  is  not  included  with  the  Fireplace  Insert, 

however it may be purchased separately and placed only on the firebox 

floor.

Do  Not  place  decorative  rock  or  rock  wool  on  the  logs  or  burner 

assembly.

Содержание DV25IN33L-1

Страница 1: ...iance is not convertible for use with other gases unless a certi ed kit is used GAS FIRED Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store...

Страница 2: ...10 12 Vertical Termination 13 Alternate ON OFF Switch Installation 14 Surround Panel Installation 15 Blower Accessory Information 16 Log Placement 17 Operating Instructions 18 Standing Pilot Lighting...

Страница 3: ...t clean Vent cap is hot while replace is in operation Installation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected before use and at least annually by a quali...

Страница 4: ...perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wal...

Страница 5: ...ng jurisdiction State of Massachusetts The installation must be made by a licensed plumber or gas tter in the Commonwealth of Massachusetts The installation must conform with local codes or in the abs...

Страница 6: ...talling to an existing round replace chimney pipe DVVK3FV Vertical Vent Kit 25 Two pieces of 25 FlexVent Rectangle Cap Flashing connectors and clamps Recommended when installing to a square or rectang...

Страница 7: ...28 14 1 2 11 1 8 25 1 4 12 3 4 17 18 5 16 27 6 3 4 9 20 25 5 8 40 DV33IN 22 3 4 31 16 14 1 8 28 1 4 14 1 4 18 3 4 21 5 16 30 8 1 4 10 1 2 21 1 2 28 5 8 43 DV35IN 24 3 4 34 16 16 1 8 31 1 4 14 1 4 21 3...

Страница 8: ...10 1 3 4 23 11 Combustible Material No greeting cards stockings or ornamentation of any type should be placed on or attached to the replace The ow of heat can ignite combustibles Figure 4 8 MINIMUM CL...

Страница 9: ...s results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the replace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural gas valves have a buil...

Страница 10: ...sting air circulation vents or grills NOTE Cutting of sheet metal parts of a replace in order to install the replace insert is prohibited WARNING Only the surround as supplied may be used to cover int...

Страница 11: ...asonry chimney may need to be removed to allow installation of the exible vent pipe When installing into a zero clearance factory built wood burning replaces the use of the DVKI Round Vertical Termina...

Страница 12: ...NT CONNECTION RETAINER SCREWS MAY BE INSTALLED THROUGH THE VENT CLAMPS TO ENSURE POSITIVE SECUREMENT OF VENTING SCREWS ADDED THROUGH VENT CLAMPS TO RETAIN VENTING TO COLLARS RECOMMENDED USE HIGH TEMP...

Страница 13: ...ly dripping out at joints or seams Condensate can cause corrosion of caps pipe and ttings It may be caused by having excessive lateral runs or having exterior portions of the system exposed to cold we...

Страница 14: ...ound panel assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides Lift the surround panel assembly slightly until the bottom return ange top pa...

Страница 15: ...FINISHING THE FIREPLACE INSERT NEVER OBSTRUCT OR MODIFY THE AIR INLET OUTLET LOUVERS ON THE FIREPLACE IN SERT IN ANY MANNER NOTE INSTALL SURROUND PANELS SO THAT THE TOP PANEL RETURN FLANGE SLIDE S OV...

Страница 16: ...nd BTU input level setting control by adjustment of the HI LO knob located on the gas valve Blower removal instructions Servicing or removal of the blower system must be performed by a quali ed servic...

Страница 17: ...support Note DV25IN models incorporate two small tabs in the rear log support that keep the back log positioned correctly DV33IN models have one small tab in the rear log support to ensure the back lo...

Страница 18: ...N position This time period allows the millivolts electrical current to build up to a suf cient level allowing the gas control to operate properly 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for sta...

Страница 19: ...switch to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a re or explosion may result causing property damage personal injury or loss of l...

Страница 20: ...ptional Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8m or less length of 18 A W G minimum wire and connect it to the replace valve pigtails WARNIN...

Страница 21: ...s from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading atTH TP TPterminals...

Страница 22: ...that no debris is interfering with the ow of air Inspect entire vent system for proper function Cleaning Logs Use a soft brush attachment on a vacuum cleaner to gently remove dust or soot deposits fr...

Страница 23: ...what your dealer can furnish contact Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finish Hammered Pewt...

Страница 24: ...23015 6 0408 Page 24 INSERT PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 39 40 41 7 12 32 42 43 18 44 45 46 48 47 49...

Страница 25: ...23a P286 P270 P244 ORIFICE MAIN BURNER NAT 23b P214 P210 P245 ORIFICE MAIN BURNER LP 24 23311 23017 23017 BURNER ASSEMBLY 25 22959 22959 22959 VALVE BRACKET 26 22739 22738 22738 TUBING ASSEMBLY 27 22...

Страница 26: ...ne the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Number Part Description Fir...

Страница 27: ...23015 6 0408 Page 27 SERVICE NOTES...

Страница 28: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: