Page 26
14. Data Processing
In order for this menu to appear, a
memory card (32MB to 2GB) must be
inserted into the analyzer.
Note: This section explains how to
save data snapshots to internal
memory. For data logging onto a
memory card, see
“6. Data Logging
onto Memory Card
”
Select:
Search or create files to save the data
snapshot
View:
View data files that have been saved
Memory (M):
Here all stored measurements (sorted
by record number) can be viewed. Sin-
gle measurement results can be called
up as follows:
- Select desired record number with the
cursor keys and confirm with
<Enter>
- Scroll with the cursor keys
- Press
<ESC>
to exit
Format:
If your memory card is not working properly, you may have to reformat.
Caution: If you reformat, all files on the memory card will be lost!
DRT <-> PC!:
Load data:
Enables the data import from e.g. rbr software (available on our
website www.rbr.de). See
Technical Data
at the end of this manual
for data format information (please observe the transfer options of
your software!).
Select
View
Memory (M)
Format
DRT <-> PC !
Datalogger
Quit with: ESC
Data processing
Date Fuel type
1 01.09.09 11:01 Fuel oil
2 01.09.09 11:02 Fuel oil
3 01.09.09 11:04 Fuel oil
4 01.09.09 11:07 Fuel oil
5 01.09.09 11:11 Fuel oil
6 01.09.09 11:23 Fuel oil
7 01.09.09 11:44 Fuel oil
8 01.09.09 11:53 Fuel oil
Select :