8. Gas Analysis
8.1. Gas analysis display screen
After the 1-minute auto-zero phase, the instrument switches over to
the measurement mode. The gas measurement values can be
viewed on 4 display pages. Press up/down to scroll between the
pages.
Note:
To view readings with O2 correction, see
Chapter 8.6
for in-
structions on how to change the units to O2-corrected values.
Pressing
<F1>
goes to “Standby“ mode which turns the pump off. If
you want to change the F1 key, go to Adjustments->Internal->F1
Hotkey. You can set the F1 key to: Soot test, Data processing, View
memory, Display values, Fuel type, Efficiency (K), Internal, Adjust-
ments.
Press
<F2>
to print out the values simultaneously to their recording
in the intermediate memory.
Press
<F3>
to start the CO purge pump. This dashes out the CO
reading on the display and introduces fresh air to the CO sensor to
protect it from over ranging
Note: The CO purge pump automati-
cally activates when the CO ppm limit is exceeded
– usually set
at 4000ppm.
Standby
<F1>
Edit line
items on
display
<F4>
values
<F2>
CO purge
pump on/off
<F3>
Peltier
cooler
ON/OFF
O2
3.2
%
CO2
13.1
%
T.Gas
184
°C
T.Air
20
°C
BImSchV