8.2 Switching Between Fuel Sources
8.3
It is common for customers who use the IAQH-1000 heating system to switch between
fuel sources as they become available during the construction process. This typically
involved starting projects on propane fuel, and switching to natural gas when it becomes
available.
The unit is equipped with a quick change lockable orifice valve to switch between fuel orifices.
The valve is labeled and includes a lockable connection to allow the position to be set, and
locked.
It is very important that the valve be set in the correct position for your fuel selection, ITEM 17 is
the orifice valve, and is open for natural gas, and closed for propane operation.
Each time a fuel change occurs, following the section 4.3 startup and commissioning
instructions.