WARNING! 

Petroleum coke fuels or household waste must not 
be burnt on this appliance. Do not use treated 
timber. 
Should any difficulties arise over fuel quality or 
suitability, consult your local approved coal 
merchant or: 
HETAS Ltd. 
Telephone 01684 278170 – www.hetas.co.uk 
Solid Fuel Association 
Telephone 0845 601 4406 – www.solidfuel.co.uk 

 
WOOD LOGS 

Ensure your logs are well seasoned with a moisture 
content of less than 20%. 
Maximum 
Length:      235mm (9 3/4”)

 

 

 
 

 

 

CLEAN AIR ACT 1993 AND SMOKE CONTROL AREAS 

 

Under  the  Clean  Air  Act 1993  local  authorities  may 
declare  the  whole  or  part  of  the  district  of  the 
authority to be a smoke control area. It is an offence 
to emit smoke from a chimney of a building, from a 
furnace  or  from  any  fixed  boiler  if  located  in  a 
designated smoke control area. It is also an offence 
to  acquire  an  "unauthorised  fuel"  for  use  within  a 
smoke control area unless it is used in an "exempt" 
appliance  ("exempted"  from  the  controls  which 
generally apply in the smoke control area).  

The  Secretary  of  State  for  Environment,  Food  and 
Rural Affairs has powers under the Act to authorise 
smokeless  fuels  or  exempt  appliances  for  use  in 
smoke  control  areas  in  England.  In  Scotland  and 
Wales  this  power  rests  with  Ministers  in  the 
devolved  administrations  for  those  countries. 
Separate legislation, the Clean Air (Northern Ireland) 
Order 1981, applies in Northern Ireland. Therefore it 

is a requirement that fuels burnt or obtained for use 
in  smoke  control  areas  have  been  "authorised"  in 
Regulations  and  that  appliances  used  to  burn  solid 
fuel  in  those  areas  (other  than  "authorised"  fuels) 
have been exempted by an Order made and signed 
by the Secretary of State or Minister in the devolved 
administrations.  

Further  information  on  the  requirements  of  the 
Clean 

Air 

Act 

can 

be 

found 

here: 

http://smokecontrol.defra.gov.uk/ 

 

Your local authority is responsible for implementing 
the  Clean  Air  Act  1993  including  designation  and 
supervision  of  smoke  control  areas  and  you  can 
contact  them  for  details  of  Clean  Air  Act 
requirements.  

The  Eco  4  has  been  recommended  as  suitable  for 
use  in  Smoke  Control  Areas  when  burning  wood 
logs. 

 
 
 
 
 
 
 
 
 
 

 

 

Содержание eco 4

Страница 1: ...1 JINECO04 REV I 12 03 15 eco 4 CVSEC04FM Instructions for Installation Operating Maintenance Servicing Approved for use in the United Kingdom and the Republic of Ireland...

Страница 2: ...authorised fuels Consumables are deemed to be Glass Seals Gaskets Grate Components Log Retainers Baffles and the surface finish of the appliance The Warranty will only be valid if the appliance is ins...

Страница 3: ...nd out if you are in a Smoke Control Area by contacting your Local Authority The Eco Ideal 4 has been fitted with a permanent bypass that prevents closure of the secondary air slider Removal of this w...

Страница 4: ...temperatures on or near this appliance Do not place furniture or other items within 1 metre of the front of this appliance See the note on material clearances on page 13 Extractor Fans and or Cooker...

Страница 5: ...the presence of children the elderly or the infirm The fireguard should be manufactured in accordance with BS8423 Fireguards for use with solid fuel appliances Do not Over Fire It is possible to fire...

Страница 6: ...arbon Monoxide Detector that conforms to the latest issue of BS EN 50292 is placed in the same room as the appliance The installation of such an alarm is not considered as a substitute for regular mai...

Страница 7: ...washers Slide the remaining gasket on to the studs of the flue collar or blanking plate and secure in place on the back plate Unless the optional flue damper is being fitted blank off the damper handl...

Страница 8: ...chimney is suspected of previously serving an open fire it must be swept again within a month of regular use to clear any soot that may have been dislodged due to the variation in combustion levels a...

Страница 9: ...derstood These instructions cover the basic principles to ensure satisfactory installation of the stove although detail may need slight modification to suit particular local site conditions In all cas...

Страница 10: ...0 013 0389 Air Supply The room or space containing this appliance should have purpose provided ventilation where necessary in accordance with Building Regulations Due consideration should be given to...

Страница 11: ...cannot be reached through the stove with baffle removed a soot door must be fitted in a suitable position Flue Draught If the draught exceeds the recommended maximum a draught stabiliser must be fitt...

Страница 12: ...material or tiles at least 12mm thick The hearth should extend at least 150 mm from the sides and rear of the stove and at least 225 mm from the front of the stove All non combustible walls closer tha...

Страница 13: ...unt of air can be increased by moving the slider to the right The slider can be unlocked from its position by twisting the control knob anti clockwise Once the slider is in the desired position it can...

Страница 14: ...aper dry sticks and or firelighters in the mode chosen either wood or solid mineral fuel Light the fire at the base leaving all air controls open Allow the fuel to reach a steady glow and build the fi...

Страница 15: ...down If you want to revive the fire it is recommended that the Primary Air control is open first and then open the secondary air slider REFUELING Add the new fuel to the fire and open both air contro...

Страница 16: ...apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas...

Страница 17: ...heat up slowly ensuring that no products of combustion enter into the room When the appliance has reached working temperature open the Door and carry out a spillage test using a smoke match around th...

Страница 18: ...d with a heat resistant paint and this can be cleaned with a soft brush Do not clean whilst the stove is hot wait until it has cooled down At no point should any water based or other cleaning products...

Страница 19: ...e checked for potential obstructions by a competent person before lighting the stove DE ASHING De ashing should be carried out on a regular basis to avoid a buildup of ash and ensure sufficient primar...

Страница 20: ...ndows in the room where the appliance is fitted a strange smell when the appliance is lit or water leaking from the appliance Please consult with your installer if you are concerned in any way about t...

Страница 21: ...w FSJM05008SS Door Slider CH08003 Glass Gasket ECO06007 Door Handle Assembly ECO06ARRT005 Glass Clip HHR08164 Slider Knob HCE06059 Door Cover HEC07002 Door Glass ECO06008 Rope Sealing Kit SCPHCE09SDSK...

Страница 22: ...22 Body Assembly Spares...

Страница 23: ...escription Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney flue system been swept and passed the soundness test Has th...

Страница 24: ...Signature Signature 5th Service 6th Service Date of Service Date of Service Date of next Service Date of next Service Servicing Company Engineer Servicing Company Engineer Signature Signature 7th Ser...

Отзывы: