10
W
ARNING
!
A
FAULTY INSTALLATION CAN CAUSE DANGER
,
ILL HEALTH AND EVEN DEATH TO THE INHABITANTS AND POSSIBLY
COMPROMISE THE STRUCTURE OF THE BUILDING
.
C
OMPETENT
P
ERSONS
S
CHEME
Members of the following schemes may self-certify the installation of this stove. If the installer is not a
member of one of these schemes, your local Building Control Department must approve the installation.
Scheme
Web address
Telephone
APHC (Association of Plumbing and
Heating Contractors (Certification)
Limited
www.aphc.co.uk
0121 711 5030
Building Engineering Services
Competence Accreditation (BESCA
Limited)
www.hvca.org.uk
/
www.besca.org.uk
0800 652 5533
HETAS Ltd (Heating Equipment Testing
and Approval Scheme)
www.hetas.co.uk
01684 278170
NAPIT Registration Ltd
www.napit.org.uk
01623 811483
NICEIC Group Ltd
www.niceic.com
0870 013 0389
Air Supply
The room or space containing this appliance should
have purpose provided ventilation (where
necessary) in accordance with Building Regulations.
Due consideration should be given to air
requirements for any other appliance in the same
room or space.
Any air opening must be kept clear from blockage
or obstruction.
Chimney
The chimney height and the position of the chimney
terminal should conform to Building Regulations.
Check that the chimney is in good condition, dry,
free from cracks and obstructions. The diameter of
the flue should not be less than 127mm and not
more than 200mm. If any of these requirements are
not met, the chimney should be lined by a suitable
method.
If there is no existing chimney then either a
prefabricated block chimney in accordance with
Building Regulations Approved Document J, or a
twin-walled insulated stainless steel flue to BS EN
1856 can be used. These chimneys must be fitted in
accordance with the manufacturer’s instructions
and Building Regulations.