20
TROUBLESHOOTING:
Incorrect Flue Draught in your chimney/flue system
will cause for poor performance of your appliance.
Excessive Flue Draught can cause Poor burning
control, excessive fuel consumption and even noise
from the Air Controls.
Low Flue Draught can cause difficulty in lighting and
running the appliance, poor heat output and smoke
entering the room when the Appliance Door is
opened.
Poor quality Solid Mineral Fuel and/or damp wood
will also affect the performance of your appliance.
Please be aware of the possible warning signs that
your appliance is not functioning correctly.
Poor combustion, staining or sooting around the
appliance, condensation or dampness on walls or
windows in the room where the appliance is fitted, a
strange smell when the appliance is lit or water
leaking from the appliance.
Please consult with your installer if you are
concerned in any way about the performance of this
appliance.
TROUBLESHOOTING EXAMPLES:
FIRE WILL NOT BURN
Check that:
1. The air inlet is not obstructed in any way.
2. Chimneys and flue ways are clear.
3. A suitable fuel is being used.
4. There is an adequate air supply into the room.
5. An extractor fan is not fitted in the same room as
the stove.
6. Flue draught is above minimum level (see
installation instructions).
FIRE BLAZING OUT OF CONTROL
Check that:
1. The doors are tightly closed.
2. The air controls are all in the closed position.
3. A suitable fuel is being used.
4. The glass retaining clips are not loose.
5. The door rope seals are in good condition
6.
Flue draught is below maximum level (see
installation instructions).