PLEASE NOTE: SH22 IS FOR OUTDOOR PERMANENT INSTALLATIONS ONLY AND SH22I IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL
AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.
Designed in
Summerville, SC
Support:
Support.Eccotemp.com
Shop Online:
www.Eccotemp.com
Phone:
866-356-1992
Less than 10 Amps
C
US
SH22
-LP
140,000
25,000
120 Volts
60 Hz
150 psi
LIQUID PROPANE
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
Volta
g
e:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum W
orking P
ressure:
Recovery
Ra�ng:
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
4.93
3.62
Input (btu/hr)
Manifold pressure (in. w.c)
Not recommended in excess of 2,000 �. above sea level.
FOR YOUR SAFETY
Do not store or use
g
asoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mus
t be in
stalled in accor
dance with
local codes or, in the a
b
sence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or
CSA B149.1, Natural Gas and Propane Installation Code
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a fire retardant area, and must be away from all combus�ble materials.
Minimum clearances from combus�ble construc�on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven�ng system. Refer to the installa�on instruc�ons for parts list and
method of installa�on.
OUTDOOR USE ONLY
11 in. w.c
13.5 in. w.c
4.93 in. w.c
(1.23 Kpa)
Éléva�on
Non recommandé à plus de 2000 pieds
au-dessus du niveau de la mer.
Less than 10 Amps
C
US
SH22
-NG
140,000
25,000
120 Volts
60 Hz
150 psi
NATURAL GAS
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
Volta
g
e:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum W
orking P
ressure:
Recovery
Ra�ng:
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
3.05
3.05
Input (btu/hr)
Manifold pressure (in. w.c)
Not recommended in excess of 2,000 �. above sea level.
FOR YOUR SAFETY
Do not store or use
g
asoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mus
t be in
stalled in accor
dance with
local codes or, in the a
b
sence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or
CSA B149.1, Natural Gas and Propane Installation Code
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a fire retardant area, and must be away from all combus�ble materials.
Minimum clearances from combus�ble construc�on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven�ng system. Refer to the installa�on instruc�ons for parts list and
method of installa�on.
OUTDOOR USE ONLY
5.0 in. w.c
10.5 in. w.c
3.05 in. w.c
(0.76Kpa)
Eleva�on
Less Than 10 Amps
C
US
SH22
i-LP
140,000
25,000
11 in. w.c
120 Volts
13.5 in. w.c
60 Hz
4.93 in. w.c
(1.23 Kpa)
150 psi
LIQUID PROPANE
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Raing (Btu per hour):
Maximum Input Raing (Btu per hour):
Voltage:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum Working Pressure:
Recovery
Ra
ti
ng:
As used in this standard, the quanity of water obtained by multplying the
manufacturer's input raing in Btu per hour by the thermal
efficiency
and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUITABLE FOR WATER (POTABLE) HEATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
4.93
3.62
Input (btu/hr)
Eleva
ti
on
Manifold pressure (in. w.c)
Not recommended in excess of 2,000
ft
. above sea level.
Category III Water Heater
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance must be installed in accordance with
local codes or, in the absence of local codes, the
The temperature and pressure relief valve provided by the manufacturer shall be installed at the
ti
me of
installa
ti
on of the heater in the loca
ti
on spec
ifie
d by the manufacturer. Local codes shall govern
installa
ti
on of relief devices. For safe opera
ti
on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a
fire
retardant area, and must be away from all combus
ti
ble materials.
Minimum clearances from combus
ti
ble construc
ti
on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven
ti
ng system. Refer to the installa
ti
on instruc
ti
ons for parts list and
method of installa
ti
on.
Less Than 10 Amps
C
US
SH22
i-NG
140,000
25,000
5.0 in. w.c
120 Volts
10.5 in. w.c
60 Hz
3.05 in. w.c
(0.76Kpa)
150 psi
NATURAL GAS
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra
�
ng (Btu per hour):
Maximum Input Ra
�
ng (Btu per hour):
Voltage:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum Working Pressure:
Recovery
Ra
�
ng:
As used in this standard, the quanity of water obtained by mul
�
plying the
manufacturer's input ra
�
ng in Btu per hour by the thermal
efficiency
and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUITABLE FOR WATER (POTABLE) HEATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
3.05
3.05
Input (btu/hr)
Manifold pressure (in. w.c)
Not recommended in excess of 2,000
�
. above sea level.
Category III Water Heater
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance must be installed in accordance with
local codes or, in the absence of local codes, the
The temperature and pressure relief valve provided by the manufacturer shall be installed at the
�
me of
installa
�
on of the heater in the loca
�
on spec
ifie
d by the manufacturer. Local codes shall govern
installa
�
on of relief devices. For safe opera
�
on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a
fire
retardant area, and must be away from all combus
�
ble materials.
Minimum clearances from combus
�
ble construc
�
on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven ng system. Refer to the installa
�
on instruc
�
ons for parts list and
method of installa
�
on.
Eleva on
INDOOR USE ONLY
INDOOR USE ONLY
Non recommandé à plus de 2000 pieds
au-dessus du niveau de la mer.
Less than 10 Amps
C
US
SH22
-NG
140,000
25,000
120 Volts
60 Hz
150 psi
NATURAL GAS
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
Volta
g
e:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum W
orking P
ressure:
Recovery
Ra�ng:
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
3.05
3.05
Input (btu/hr)
Manifold pressure (in. w.c)
Not recommended in excess of 2,000 �. above sea level.
FOR YOUR SAFETY
Do not store or use
g
asoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mus
t be in
stalled in accor
dance with
local codes or, in the a
b
sence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or
CSA B149.1, Natural Gas and Propane Installation Code
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a fire retardant area, and must be away from all combus�ble materials.
Minimum clearances from combus�ble construc�on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven�ng system. Refer to the installa�on instruc�ons for parts list and
method of installa�on.
OUTDOOR USE ONLY
5.0 in. w.c
10.5 in. w.c
3.05 in. w.c
(0.76Kpa)
Eleva�on
Non recommandé à plus de 2000 pieds
au-dessus du niveau de la mer.
Less than 10 Amps
C
US
SH22
-NG
140,000
25,000
120 Volts
60 Hz
150 psi
NATURAL GAS
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
Volta
g
e:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum W
orking P
ressure:
Recovery
Ra�ng:
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
3.05
3.05
Input (btu/hr)
Manifold pressure (in. w.c)
Not recommended in excess of 2,000 �. above sea level.
FOR YOUR SAFETY
Do not store or use
g
asoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mus
t be in
stalled in accor
dance with
local codes or, in the a
b
sence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or
CSA B149.1, Natural Gas and Propane Installation Code
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a fire retardant area, and must be away from all combus�ble materials.
Minimum clearances from combus�ble construc�on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven�ng system. Refer to the installa�on instruc�ons for parts list and
method of installa�on.
OUTDOOR USE ONLY
5.0 in. w.c
10.5 in. w.c
3.05 in. w.c
(0.76Kpa)
Eleva�on
Non recommandé à plus de 2000 pieds
au-dessus du niveau de la mer.
Less than 10 Amps
C
US
SH22
-NG
140,000
25,000
120 Volts
60 Hz
150 psi
NATURAL GAS
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Ra�ng (Btu per hour):
Maximum Input Ra�ng (Btu per hour):
Volta
g
e:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum W
orking P
ressure:
Recovery
Ra�ng:
As used in this standard, the quan�ty of water obtained by mul�plying the
manufacturer's input ra�ng in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUIT
ABLE
FOR WA
TER (P
OT
ABLE) H
EATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
3.05
3.05
Input (btu/hr)
Manifold pressure (in. w.c)
Not recommended in excess of 2,000 �. above sea level.
FOR YOUR SAFETY
Do not store or use
g
asoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance mus
t be in
stalled in accor
dance with
local codes or, in the a
b
sence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or
CSA B149.1, Natural Gas and Propane Installation Code
The temperature and pressure relief valve provided by the manufacturer shall be installed at the �me of
installa�on of the heater in the loca�on specified by the manufacturer. Local codes shall govern
installa�on of relief devices. For safe opera�on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a fire retardant area, and must be away from all combus�ble materials.
Minimum clearances from combus�ble construc�on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven�ng system. Refer to the installa�on instruc�ons for parts list and
method of installa�on.
OUTDOOR USE ONLY
5.0 in. w.c
10.5 in. w.c
3.05 in. w.c
(0.76Kpa)
Eleva�on
Less Than 10 Amps
C
US
SH22
i-LP
140,000
25,000
11 in. w.c
120 Volts
13.5 in. w.c
60 Hz
4.93 in. w.c
(1.23 Kpa)
150 psi
LIQUID PROPANE
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Raing (Btu per hour):
Maximum Input Raing (Btu per hour):
Voltage:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum Working Pressure:
Recovery
Ra
ti
ng:
As used in this standard, the quanity of water obtained by multplying the
manufacturer's input raing in Btu per hour by the thermal
efficiency
and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUITABLE FOR WATER (POTABLE) HEATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
4.93
3.62
Input (btu/hr)
Eleva
ti
on
Manifold pressure (in. w.c)
Not recommended in excess of 2,000
ft
. above sea level.
Category III Water Heater
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance must be installed in accordance with
local codes or, in the absence of local codes, the
The temperature and pressure relief valve provided by the manufacturer shall be installed at the
ti
me of
installa
ti
on of the heater in the loca
ti
on spec
ifie
d by the manufacturer. Local codes shall govern
installa
ti
on of relief devices. For safe opera
ti
on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a
fire
retardant area, and must be away from all combus
ti
ble materials.
Minimum clearances from combus
ti
ble construc
ti
on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven
ti
ng system. Refer to the installa
ti
on instruc
ti
ons for parts list and
method of installa
ti
on.
Less Than 10 Amps
C
US
SH22
i-LP
140,000
25,000
11 in. w.c
120 Volts
13.5 in. w.c
60 Hz
4.93 in. w.c
(1.23 Kpa)
150 psi
LIQUID PROPANE
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
SERIAL #
:
TYPE GAS:
ONLY
Minimum Inlet Gas Pressure:
Minimum Input Raing (Btu per hour):
Maximum Input Raing (Btu per hour):
Voltage:
Maximum Inlet Gas Pressure:
Frequency:
Manifold Pressure:
Amps:
Maximum Working Pressure:
Recovery
Ra
ti
ng:
As used in this standard, the quanity of water obtained by multplying the
manufacturer's input raing in Btu per hour by the thermal
efficiency
and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
CSA/ANSI Z21.10.3 • CSA 4.3-2019
SUITABLE FOR WATER (POTABLE) HEATING ONLY
CANADIAN HIGH ALTITUDE RATING
0-2000 feet
2000-4500 feet
140,000
126,000
4.93
3.62
Input (btu/hr)
Eleva
ti
on
Manifold pressure (in. w.c)
Not recommended in excess of 2,000
ft
. above sea level.
Category III Water Heater
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance must be installed in accordance with
local codes or, in the absence of local codes, the
The temperature and pressure relief valve provided by the manufacturer shall be installed at the
ti
me of
installa
ti
on of the heater in the loca
ti
on spec
ifie
d by the manufacturer. Local codes shall govern
installa
ti
on of relief devices. For safe opera
ti
on of the water heater, the relief valve must not be removed
or plugged.
The unit must be installed on a
fire
retardant area, and must be away from all combus
ti
ble materials.
Minimum clearances from combus
ti
ble construc
ti
on, 10 inches sides, 0 inches back and 16 inches top.
This water heater requires a special ven
ti
ng system. Refer to the installa
ti
on instruc
ti
ons for parts list and
method of installa
ti
on.