PX100D_Manual_en-1.17.2i10
Page 29 / 59
7.3.3.1.
Output 1/Output 2/Output 3
These columns define which signals are to influence the status of a specific output.
Possible choices are:
o
Do Nothing
– output status will be not changed (default action)
o
Turn on output
– output will be permanently turned on
o
Turn on output temporarily
– output will be turned on for an amount of time
specified by parameter
7.3.3.2 Time of output activation
o
Turn off output
– output will be turned off
Press the [Reset] button to assign the action “Do Nothing” for each event.
The output state does not change if the current state of the output coincides with
the result of the action.
7.3.3.2.
Time of output activation
Parameter defining amount of time for which the output is to be turned on for the
functions of advanced outputs control.
7.4.
MONITORING
Thanks to this option you may determine which of available signals generated by
the device shall be transmitted to monitoring station.
NOTE: “Configuration changed” event refer to configuration changes made
by SMS or GPRS commands.
7.4.1.
GPRS On / GPRS Off
In this column you define signals that are to be reported to monitoring station with
GPRS transmission. There is possibility to send information on alarms (input state
change from rest to action status) and on returns of input state from action to rest
(normalization).
To transmit any signal you should only click it (proper square on your right).
Click on [Clear] button to remove all marked signals.
Click on [Invert] button to change markings to contrary.