7.3.
INPUTS/OUTPUTS
Transmitter has got 8 signal inputs and additional input for sabotage signal switch-
key connection. Module is equipped with three outputs: indicating sabotage and an
additional two. In/Out option enable programmable configuration so that
transmitter operates pursuant to requirements of the user.
All inputs of the device are 24 hour alarm inputs.
7.3.1.
Inputs configuration
For every input the following settings shall be determined respectively.
7.3.1.1.
NO/NC
This parameter allow for setting of constant input. Change of this state results in
sending information on alarm. Allowable NC and NO input. NC input shall be shorted
to ground. Actuation follows after decay. NO input remains open. At this moment of
shortening to ground activation follows.
7.3.1.2.
Delay [ms]
This parameter means minimum time for change maintenance at input so that it
would be detected by transmitter. Factory setting is 400ms.