7.
PROGRAMMABLE PARAMETERS
Parameters available in configuration program are divided into groups: Access,
Transmission, Inputs/Outputs, Monitoring, Restrictions, SMS Notifications, Link
control, RS-232, Dialer and Firmware. Every from these groups will be described in
detail in next part of this manual.
7.1.
ACCESS
7.1.1.
Parameters
7.1.1.1.
Device mode
Depending of user preferences, a device may operate in 1 out 4 modes (available
from scrolled list) :
o
GPRS & SMS
: GPRS standard transmission (TCP/IP Protocol), and if any
problems follow with this link it automatically SMS mode will follow.
o
SMS
: Transmission only in SMS mode, without trial to establish GPRS link
o
GPRS
: GPRS standard transmission (TCP/IP Protocol), and in case of any
problems with this link no transmission will follow.
o
Serverless
: no transmission to the server is possible, remote communication
possible only via SMS notifications to the user or dialer