EPX400-xC – Manual
Page 41 / 73
8.3.3.
Outputs
Tabs "Output 1 (OUT1)", "Output 2 (OUT2)" and "Output 3 (NC-NO-C)" define the
outputs parameters. The options for the outputs are common and are described in a
single section.
8.3.3.1.
Activation mode and timing
Thanks to this option you may choose output operation mode. There are two
operation modes available:
o
bistable – connection follows for indefinite time – up to the moment of
disconnection of power for module or remote command which switches output
off,
o
monostable – connection follows for time defined by user – every 100ms.
8.3.3.2.
Conditions
Defines conditions for activating both of outputs. User can set following conditions:
No connection to server (immediately after detection);
No GSM signal (immediately after detection);
Detection of incoming call from defined telephone number;
After selecting this option can be generated CLIP event, if appropriate position
in the “Monitoring” group is set (see item
). You can enter
full phone number or only a part of number. The device will detect all
numbers with specified sequence. E.g. if entered number is
1234
, the output
will activate after incoming call from number
1234
56789 or 600
1234
56.
Содержание EPX400-5C
Страница 20: ...EPX400 xC Manual Page 20 73...
Страница 63: ...EPX400 xC Manual Page 63 73...