EPX400-xC – Manual
Page 15 / 73
6.
PRE-CONFIGURATION VIA ETHERNET PORT
To enable the EPX400 to communicate properly, you need to provide basic server
connection parameters. The simplest way to do this is via the built-in web server
WWW.
To access the server, connect the EPX400 using an Ethernet cable to a PC that has
an RJ-45 Ethernet port and a web browser.
The device is equipped with Auto MDI-MDIX function – supports straight-through and
crossover cable. Connection does not require network switch.
The default settings of the device is IP=192.168.7.7 , mask = 255.255.255.0 and the
following description applies to such settings.
6.1.
LOGGING IN
You must configure the Ethernet interface to which the device is connected, you need
to manually set the appropriate IP address for example. 192.168.7.42 (Control Panel
\ Network and Internet \ Network and Sharing Center -> Connections-> Properties->
Internet Protocol Version 4 (TCP / IPv4) -> Properties - for Windows 10) and the
mask of 255.255.255.0.
In the Web browser, enter the device address
http://192.168.7.7
There will appear the home page described below. Service code is the password.
NOTE: The address of the EPX400 network and the computer to which the device is
connected should be the same, and the IP addresses should be different.
Содержание EPX400-5C