background image

 
AVA PRO - Assembly instructions for the CPX300W alarm control panel

  

6

 

/

 

23

 

5.

 

Applications with which the device works:

 

 

EBS  Config  2.0  in  the desktop  version  -  a  computer  program for  installers  used to  configure 
the system, 

 

EBS Config 2.0 in the smartphone version - a mobile application for installers used to configure 
the system, 

 

EBS Security - a mobile application for users to manage the system. 

6.

 

Inputs:

 

 

8 surge protected wire lines, 

 

TEOL configuration can be increased up to 16 wire lines, 

 

7 types of wired lines (NO / NC / EOL-NO / EOL-NC / DEOL-NO / DEOL-NC / TEOL), 

 

64 wireless lines (for wireless device data communication), 

 

15 types of reactions. 

7.

 

Outputs:

 

 

3 low-current wire outputs 100 mA rated, 

 

1 high-current wired output 1.1A current rated, 

 

7 functions. 

8.

 

Power outputs:

 

 

2 13.8 V power outputs (AUX1 +, AUX2 +), 

 

Power line rating: 350 mA, 

 

Overcurrent and overvoltage-protected 

9.

 

Users:

 

 

1 administrator, 

 

31 users, 

 

2 categories. 

10.

 

Configuration:

 

 

Local using EBS programmers, 

 

Remote via GPRS, SMS, Ethernet / Wi-Fi. 

11.

 

Programmers

:

 

 

MINI-PROG-BT

 - a programmer that allows configuration and monitoring of the control panel 

thanks to the IDC10 connector and Bluetooth technology. 

 

GD-PROG

  -  a  programmer  that  has  an  RS232  connector  to  a  computer  and  an  IDC10 

connector  for  configuring  and  monitoring  the  control  panel  status  using  the  EBS  Config  2.0 
program. 

 

SP-PROG

 - a programmer in two variants: 

o

 

SP-PROG,  having  an  RS232  connector  for  connection  to  a  computer  and  USB  for 
configuring and monitoring the control panel status using the EBS Config 2.0 program. 

o

 

SP-PROG-BT, having a micro USB connector, RS232 and a built-in Bluetooth module. For 
cable  connection,  the  situation  is  the  same  as  for  SP-PROG.  For  Bluetooth  technology, 
both  at  the

  Configuration  port

  and  the 

Information  port

  position,  the  same  port  for 

communication must be set. 

12.

 

Additional information:

 

 

4 partitions 

 

1 keypad is used to manage 1 partition, 

 

Up to 8 KP3W keypad can be added to the system, 

 

Multiple keyboards can be added to 1 partition, 

 

Up to 8 PIR-CAM-30 motion detectors with camera can be added to the system, 

 

Up to 8 BM8000PLx-C3W wireless siren can be added to the system, 

Содержание AVA PRO CPX300W

Страница 1: ...EN AVA PRO Control panel CPX300W Firmware version 3 1 7 Instructions version v1 3 Release date 26 05 2020 Assembly instructions for the AVA PRO CPX300W alarm control panel...

Страница 2: ...y kind either expressed or implied are provided including but not limited to any implied warranties of merchantability or suitability for a certain purpose unless such a required by law The manufactur...

Страница 3: ...module 12 3 4 WiFi 12 3 4 1 Description 12 3 4 2 Module installation 12 3 4 3 Technical parameters 13 3 5 RF433 13 3 5 1 Description 13 3 5 2 Module installation 13 3 5 3 Technical parameters 14 3 5...

Страница 4: ...nel along with a discussion of the parameters and operating principles The information contained herein will allow a quick and trouble free installation NOTE All information regarding the AVA PRO syst...

Страница 5: ...ic contact with an additional input PIR 30 motion detector PIRC AM 30 motion detector with a camera RC 30 remote control STAG 30 touchless user identifier AVA KEY BM8000PLx C3W visual audible wireless...

Страница 6: ...a GPRS SMS Ethernet Wi Fi 11 Programmers MINI PROG BT a programmer that allows configuration and monitoring of the control panel thanks to the IDC10 connector and Bluetooth technology GD PROG a progra...

Страница 7: ...required min 20 VA Current consumption 18VAC average max 85 mA 130 mA 18VAC in 2G mode with MOD GSM 2G modem uBlox Sara G350 78 mA 130 mA 18VAC in 3G mode with MOD GSM 3G modem uBlox Sara U201 Current...

Страница 8: ...onnected battery but without the mains power supply MODE user base formatting button including installer code To run the process press the button turn on the power supply of control panel holding for...

Страница 9: ...built in 868 MHz module Place for a latch securing the antenna wire included to the module together with the set P1 P2 P3 P4 Yellow LEDs indicating the signal level for the GSM module Steady light rep...

Страница 10: ...on the CPX300W motherboard labelled cellular network see Figure 1 item 6 and then screwed with a screw attached to the set The module has two sockets for mounting nano SIM cards To place the card sli...

Страница 11: ...icantly reduce its range 3 2 5 Technical parameters of the GSM module Table 2 Technical parameters of the GSM module Module variant 2G 3G Modem SARA G350 SARA U201 Supported frequency bands 2G 850 MHz...

Страница 12: ...Ethernet module Table 3 Technical parameters of the Ethernet module Supported connection standards 10Base T 100Base TX Auto MDI MDI X Ethernet connector RJ45 shielded Dimensions 36 5 mm x 27 mm 3 4 W...

Страница 13: ...266EX 3 5 RF433 3 5 1 Description A radio communication module cooperating with the CPX300W alarm control panel powered directly from the control panel motherboard This module enables to add one way d...

Страница 14: ...5 mm 3 5 4 433 MHz antenna The set includes two types of antennas Internal wire antenna An internal antenna can be used wherever compactness is required and it provides the appropriate level of detec...

Страница 15: ...alarm control panel with the elements of Smart Home Connector for installation of the module u FL antenna connection Mounting hole for the screw Fig 8 View of MOD Z Wave module boards with description...

Страница 16: ...Logged in correctly to the GSM network lights steadily flashes Table 8 Ethernet Wi Fi network login indication LED indicator Description STATUS green ETH WiFi yellow Ethernet Wi Fi network login attem...

Страница 17: ...l which results in switching off all 15 LEDs for about 1 second and then lighting all LEDs also for about 1 second 3 7 4 No SIM card or damage to the SIM card After detection of the main SIM card in t...

Страница 18: ...this signal is correct you can proceed to the proper permanent installation of the system 4 Perform the remaining cable connections 5 Connect the battery to the screw terminals BAT BAT and then the e...

Страница 19: ...icks Loss 5 35 Reinforced concrete or metal substrate Loss 30 90 Fig 11 Loss of radio signal strength after passing through various materials 4 3 Location of wireless detectors When installing devices...

Страница 20: ...an alarm DEOL NO a line type for connecting detectors with a normally open alarm output NO and a tamper output The input distinguishes three states normal alarm and sabotage DEOL NC a line type for co...

Страница 21: ...AVA PRO Assembly instructions for the CPX300W alarm control panel 21 23 Fig 12 Configuration of the input line Detector No 1 Detector No 2...

Страница 22: ...l panel 22 23 4 5 An example of connecting the siren without battery Fig 13 An example of connecting an internal siren without battery 4 6 An example of connecting the siren with own battery Fig 14 An...

Страница 23: ...vision Firmware Description 2019 07 12 w1 0 3 0 2 First version of the manual 2019 12 06 w1 1 3 1 0 Description of the MODE button technical specification updated 2020 02 27 w1 2 3 1 5 Technical speci...

Отзывы: