AVA PRO - Assembly instructions for the CPX300W alarm control panel
17
/
23
The signalling of the range is interrupted during data transmission, and after sending the data the GSM
range is shown again.
3.7.3.
Programming
Entering the programming mode is indicated by a synchronous flashing:
yellow P1, P2, P3, P4 LEDs (fig. 1, item 20),
green STATUS LEDs (Fig. 1, item 22),
yellow LED at IDC10 connector (fig. 1, item 14).
The output from the programming resets the control panel, which results in switching off all 15 LEDs for about 1
second, and then lighting all LEDs also for about 1 second.
3.7.4.
No SIM card or damage to the SIM card
After detection of the main SIM card in the GSM module, the yellow LED indicating the presence of the
card will turn on (fig. 3, item 3). An attempt to connect to the GSM network will start - the STATUS LED
will flash and the CELL will light steadily. After successful connection, the STATUS LED will light steadily
and the CELL LED will flash. If a second SIM card is used, it is necessary to configure the control panel
correctly - see chapter "
Use a spare SIM card
" in the EBS Config 2.0 instruction manual.