Temperature menu 

TEMP

The temperature menu contains the functions that in some way concern direct tem-
perature regulation. This is where the set point, hysteresis and temperature alarm 
are set. The temperature menu is reached via 

TEMP

 in the 

MAIN MENU

.

Set point 

TEMP

The set point can be set to an accuracy of 0.5 degrees and is set in two overlapping 
ranges. The lower temperature range is from -15 °C to +75 °C and the upper from 0 °C 
to +150 °C. The factory setting is +40 °C or +100 °C depending on the temperature 
range selected. 

The set point setting is under 

TEMP

 in the 

TEMP

 menu. Set the required temperature 

by pressing 

 or 

 and then confirm with 

Operation mode Industry is used to regulate the temperature of 

industrial processes, high temperatures or for the frost protection of 

sensitive installations. Temperatures within the ranges -15 °C to +75 

°C and 0 °C to +150 °C can be regulated in this mode or the range 

can be limited to between -10 °C and +15 °C for frost protection 

purposes. It is also possible to adjust temperature hysteresis and 

set upper and lower temperature alarms.

Main menu 

MAIN MENU

The 

MAIN MENU

 contains three submenus: 

TEMPERATURE

PROGRAM

 and 

SYSTEM

From display mode, go to the 

MAIN MENU

 by pressing   once. Use the   or 

 buttons to move between the menus and confirm using  .

If you do not press a button for 30 seconds, the thermostat returns to dis-
play mode; you can also return to display mode by selecting 

EXIT

.

Operation mode Industry

* Read more about temperature hysteresis and how to set it on page 23.

PROGRAM

LOW TEMP
HIGH TEMP
FROST PRO
EXIT

SYSTEM

LANGUAGE
DATE/TIME
S/W TIME
SENSOR
RESET
EXIT

EXIT

DISPLAY MODE

M

A

IN MENU

TEMP

TEMP
TEMP HYS

EXIT

ALARMS

Содержание EB-Therm 800

Страница 1: ...EB Therm 800 EN MANUAL EB Therm 800 Multifunctional digital thermostat with four operation modes for DIN installation...

Страница 2: ...y suit your own temperature needs It is important to read the manual carefully since for the guarantee to be valid the product must be installed and used in accordance with it This applies to both the...

Страница 3: ...n menu 11 Temperature menu 11 Program menu 12 System setting menu 15 Operation mode Cooling 18 Main menu 18 Temperature menu 18 Program menu 18 System setting menu 21 Operation mode Industry 24 Main m...

Страница 4: ...ram for roof installations It must be permanently in the shade e g on the north side or a shade side Ensure that it is not affected by heat emittance from the building or a heating cable 4 Roof sensor...

Страница 5: ...t If the room sensor is installed in an appliance box it must be sealed to pre vent the air temperature being affected by draught For other types of operation and control the temperature sensor can be...

Страница 6: ...snow and ice The temperature range is adjustable between 20 C and 10 C For the best results and the best energy saving combined temperature and humidity control should be used in the Max Min position...

Страница 7: ...mostat always opens in display mode see page 9 The thermostat has two modes for background lighting full and half strength If no buttons are pressed for 30 seconds the background lighting reverts to h...

Страница 8: ...start to blink Repeat this procedure until all the val ues are set Start by setting the applicable date month and year Then set hours and minutes Operation mode OPERATION MODE There a four operation...

Страница 9: ...mode press to go to the main menu From the main menu you can reach all settings read more about the main menu under the section for the selected operation mode To return to the display mode wait thir...

Страница 10: ...Then you come directly to the language menu read more about the language menu under the section concerning the selected operation mode Shortcut to temperature setting press 3 s To quickly change the...

Страница 11: ...protection are set The temperature menu is reached via TEMP in the MAIN MENU Set point TEMP The set point setting is under TEMP in the temperature menu Set the re quired temperature by pressing or an...

Страница 12: ...t point and the thermostat maintains that temperature Program for home environment HOME The temperature is lowered automatically by 5 C at the following times Monday Friday 08 30 15 00 and every day b...

Страница 13: ...rogram without the timer function select NO and the program will then be active until another program is started If you select YES the program will remain active for the selected time and will then re...

Страница 14: ...they shall occur at and the required floor temperature at that time Start by setting the time which is blinking Browse with the or the button to the time you want the event WAKE to occur First set ho...

Страница 15: ...r the set point is changed in the TEMP menu the thermostat will react based on the new temperature REMOTE CONTROL The Hotel program is controlled by a remote control device such as a card reader conne...

Страница 16: ...at calculates when heating should be started to provide the required temperature at the right time The function is activated on delivery but can be switched off as required You will find the settings...

Страница 17: ...ou want to calculate the energy consumption for a certain period The thermostat also has a counter that cannot be reset which shows the total hours the installation has been connected for To see the t...

Страница 18: ...rograms for home or office environments one program for personal settings and a holiday program There is no need to consider the cooling time when programming since the thermo stat has an adaptive fun...

Страница 19: ...raised automatically by 5 C apart from at the following times Monday Friday 06 00 18 00 The office environment program is under PROGRAM in the MAIN MENU Select OFFICE using and a message is shown for...

Страница 20: ...27 C and deletes all the time settings REMOTE CONTROL The holiday program can be controlled via a remote control unit The unit is connected to the applicable terminal block see the wiring diagram The...

Страница 21: ...ion which resets the program to the factory set ting 22 C and deletes all the time settings System setting menu SYSTEM Under system settings you will find settings for for example language and date as...

Страница 22: ...ired temperature at the right time The function is activated on delivery but can be switched off as required You will find the settings for adaptive function in the MAIN MENU under SYSTEM and there yo...

Страница 23: ...ODE The settings can be reset in OP MODE COOLING All programs are reset and the temperature and sensor settings return to the output values Resetting does not affect the choice of OP MODE LANGUAGE or...

Страница 24: ...temperatures or for the frost protection of sensitive installations Temperatures within the ranges 15 C to 75 C and 0 C to 150 C can be regulated in this mode or the range can be limited to between 10...

Страница 25: ...ssing The temperature alarm is not activated in the factory settings The function is in the ALARM menu under TEMP in the MAIN MENU Activate the temperature alarm in the ALARM menu under ON OFF and the...

Страница 26: ...connected as B terminal block 7 and 8 Low temperature program LOW TEMP This program limits the temperature range to between 15 C and 75 C This program is provided for two reasons partly to minimise t...

Страница 27: ...iod of more than fifty hours The setting function then comes up automatically The date and time setting is in the MAIN MENU under SYSTEM and DATE TIME Change the value that blinks with either or and c...

Страница 28: ...by pressing and confirming with Reset the operation mode settings OP MODE Settings can be reset in OP MODE INDUSTRY All programs are reset and the temperature and sensor settings return to the output...

Страница 29: ...emperature range is adjustable between 20 C and 10 C For the best results and the best energy saving combined temperature and humidity control should be used in the Max Min position with associated Ro...

Страница 30: ...then ON to switch off the timer select OFF When OFF or ON have been selected a message is shown for two seconds confirm ing that the function has been activated or deactivated In the factory set ting...

Страница 31: ...s for three sec onds Then go directly to the language menu A practical function if you by mistake set the wrong language and then have difficulty finding the lan guage menu again Date and time DATE TI...

Страница 32: ...ction time CONN TIME The connection time is shown in hours as with a vehicle trip meter it shows the number of hours an installation has been connected for since it was last reset This is beneficial i...

Страница 33: ...If you choose to reset the thermostat it is important to know the operation mode it uses and the con figuration of the sensors The only way to change operation mode is to reset to the factory settings...

Страница 34: ...EXCESS TEMP ALARM blinking display SUB TEMP ALARM blinking display OVER HEATING PROTECTION ACTIVE If you have forgotten to make a setting in the start up menu you must go back in the menu and make the...

Страница 35: ...1 Connection difference Adjustable 0 3 to 10 3 C Encapsulation class IP20 Reserve power 50 hours Max length sensor cable 50 m 2x1 5mm Alarm relay 2 A 120VAC Normal connection Installation Standard DIN...

Страница 36: ...EBECO AB L rje gatan 11 415 02 G teborg SWEDEN Phone 46 31 707 75 50 Fax 46 31 707 75 60 ebeco com info ebeco se EBT800 EN vers 2 0 210521...

Отзывы: