11
Operation mode Heating
Heating mode is used in homes, offices, storerooms and such like.
With this operation mode, you can regulate the heating within a
temperature range of +5 °C to +45 °C. The thermostat can be used
as a floor thermostat, room thermostat or room thermostat with over
heating protection for wood floors. The energy saving program is
primarily adapted for home and office environments, but can also be
used for regulating heating levels in, for example, storerooms.
Main menu
MAIN MENU
MAIN MENU
contains three submenus:
TEMP
,
PROGRAM
,
SYSTEM
and
EXIT
, which
returns you to display mode.
Temperature menu
TEMP
The temperature menu contains the functions that in some way concern
direct temperature regulation. This is where the set point and, if applicable,
over heating protection are set. The temperature menu is reached via
TEMP
in the
MAIN MENU
.
Set point
TEMP
The set point setting is under
TEMP
in the temperature menu. Set the re-
quired temperature by pressing or and confirm by pressing . The
set point can be set to an accuracy of 0.5 degrees within the range +5 °C to
+45 °C; it is preset to +22 °C.
Over heating protection
OH PROTECTION
Over heating protection works as a floor temperature limiter; if you have a
wood or laminate floor, you must always use a room sensor with over heating
protection to ensure that the floor material is safeguarded against over
heating and damage.
Over heating protection is under
OH PROTECTION
under
TEMP
. The limitation
can be set b5 °C and +45 °C. The factory setting is +35 °C, which
gives a surface temperature of about +27 °C.
TEMP
TEMP
OH
PROTECTION
EXIT
PROGRAM
MANUAL
HOME
OFFICE
HOLIDAY
PERSONAL
EXIT
SYSTEM
LANGUAGE
DATE/TIME
S/W TIME
SENSOR
RESET
EXIT
EXIT
DISPLAY MODE
M
A
IN MENU
ADAPTIVE
VENT
HOTEL