6.3.6 Setting the WARNING value for the pump N2 flow
Use the up and down arrow keys to change the setting value.
▲
: Increase the setting value by 0.1 Pam
3
/s
▼
: Decrease the setting value by 0.1 Pam
3
/s
Upper limit 81.0 Pam
3
/s
Lower limit 2.0 Pam
3
/s
Factory setting 4.0 Pam
3
/s
Reset value for WARNING set value +1.0 Pam
3
/s
6.3.7 Setting the WARNING value for the back pressure (option)
Use the up and down arrow keys to change the setting value.
▲
: Increase the setting value by 0.5 kPa.
▼
: Decrease the setting value by 0.5 kPa.
Upper limit : 20.0 kPa
Lower limit : 5.0 kPa
Factory setting : 10.0 kPa
WARNING reset value : Set value –2.0 kPa
Use the keys, ”
▲
” and ”
▼
” to set.
SET ALARM SP
BACK PRES.?
PRG.
ENTER
ENTER
BACK PRES.SP
##.# kPa
Setting
done
▲
▼
▲
▼
SET POINT
N2 FLOW LOW?
PRG.
ENTER
ENTER
N2 FLOW LOW
# # .# Pam
3
/s
SETTING COMPLETED