6.3.1 Setting the pump operation control mode
A case of display if Local mode selected.
REMOTE MODE : Enables the remote operation
(start/stop with external signals)
LOCAL MODE : Enables the local operation
(start/stop with the LCD controller)
COM MODE : Enables the communication operation
(start/stop with RS232C communication)
The mode that is currently not set is displayed.
If you do not need to set, press PRG. key to go back to the previous screen.
6.3.2 Setting the DIP switch
See 6.4 for details of the DIP switch.
SET
CONTROL MODE
?
PRG.
PRG.
ENTER
ENTER
ENTER
COM MODE?
REMOTE MODE?
Setting done
Setting done
The up and down arrow keys, “
▲
” and “
▼
,
” turn On and OFF the DIP switch.
The key BZ.OFF switches the selection
from 1 to 8.
A1 ON ロ ロ
OFF ロ ロロロロロ
SET
DIP SW?
PRG.
PRG.
ENTER
ENTER
SET
DIP SW C?
SET
DIP SW A?
C1 ON
OFF ロロロロロロロロ
▽
△
ENTER
SETTING COMPLETED
A1:DATA LENGTH
8BIT
C1:PUMP N2 WARN
OUTPUT N.OPEN
PRG.
ENTER
ENTER