4.3
Connection of the NETWORk TENSION
Network
230 Vac
230 Vac. The line of power supply towards the control board must
always be protected with an electromagnetic switch or with a 5A fuse
couple.
A differential switch is recommended but not indispensable if it is alre
-
ady present in the installation.
4.5
Connection of the SIGNAL LIGhT
4 5 6
4 5 6
26 27
Signal light complete with
intermittent electronic card
Signal light without
intermittent electronic card
If you are expecting to use the test on the
photocells or for a 24V light, you can’t use this
connection.
4.6
Connection of a 24Vdc light with an open and moving gate
28 29 30 31
20 21
If you are expecting to use the test on the photocells or
for a signal light, you can’t use this connection.
DIP 9 A
ON
Fix Light
4.4
Motor connection
6
7
4
Be particularly careful in not mistaking the Opening pole with the
Closing pole.
In case you have doubts about the correct connections, put ma-
nually, if possible, the gate in the middle position of the course. Be
ready to block the system with the STOP command!
1 2 3
8
9
10
11
5
MOTOR 2
Common
Open
Close
MOTOR 1
Common
Open
Close
ON
CTS
2
1
4
3
6
5
8
7
10
9
START-S4XL
Technical manual
-8-
Содержание NOLOGO START-S4XL