background image

11 

Declaration of CE conformity

START-S4XL

Technical manual

-23-

(according to EC Directive 2006/42, Attachment II, part 1, ses. A)

The undersigned 

 Ernestino Bandera, 

Administrator

 

DECLARES ThAT:

Dairago, 14 june 2007

The Administrator

Ernestino Bandera

Company:  

EB TEChNOLOGY SRL 

Address:  

Corso Sempione 172/5  

 

 

 

21052 Busto Arsizio VA Italy

 

Product’s name:

 START-S12

  

Centrale Inverter 230Vac

EB TEChNOLOGY  S.r.l. 

Corso Sempione 172/5, 

 

21052 Busto Arsizio VA Italy 

tel. +39 0331.683310

fax.+39 0331.684423 

 

[email protected]   

www.ebtechnology.it

NOLOGO S.r.l. 

via Cesare Cantù 26, 

 

20020 Villa Cortese MI Italy 

tel. +39 0331.430457 

fax.+39 0331.432496 

 

[email protected]   

www.nologo.info

ThE PRODUCT COMPLIES

with what is outlined in the European Community directive:

2006/42/CE

EC DIRECTIVE 2006/42 ISSUED BY THE EUROPEAN PARLIAMENT AND 

COUNCIL on may 17, 2006 harmonizing the legislation of the member countries 

regarding machinery.

Reference: 

Attachment II, part 1, ses. A

 (EC Declaration of Conformity issued by the manufacturer).

ThE PRODUCT COMPLIES

with what is outlined in the European Community directives:

2006/95/CE 

EEC DIRECTIVE 2006/95 ISSUED BY THE EUROPEAN COUNCIL on December

12, 2006 harmonizing the legislation of the member countries regarding electric

materials for use within certain voltage limits

Reference to harmonized standards:   EN 60335-1

2004/108/CE 

EEC DIRECTIVE 2004/108/CE ISSUED BY THE EUROPEAN COUNCIL on 

December 15, 2004, harmonizing the legislation of the member countries regarding

electromagnetic compatibility.

Reference to harmonized standards:   EN 61000-6-2     EN 61000-6-3

IL PRODOTTO E’ CONFORME

with the essential requirements of article 3 of the following

European Community Directive, for the use for which the

product is designede

1999/5/CE 

EC DIRECTIVE 1999/5 ISSUED BY THE EUROPEAN PARLIAMENT AND

COUNCIL on March 9, 1999 regarding wireless units and telecommunications

terminals and their reciprocal recognition

Reference to harmonized standards:  ETSI EN 300 220-3     ETSI EN 301 489-1     ETSI EN 301 489-3

The directive 2006/42/CE remind that it is not allowed the function of the product until the machine, for which 

the product is included, is not indentify and declared conformed to the 2006/42/CE directive. 

Содержание NOLOGO START-S4XL

Страница 1: ...photocell START 24 Vac 24 Vac 12Vac elect lock 12Vac elect lock STOP 26 27 Light Lamp Light Lamp 28 29 Phototest 24 Vac 12 Vac Lamp or courtesy light 230Vac Ground Connection 2 9 10 11 Motor 2 COMMON...

Страница 2: ...hat you contact the competent public agencies the waste collection service or the shop where you purchased the product Small legend OLS Open limit switch CLS Close limit switch START Control to drive...

Страница 3: ...e products 1 1 Safety precautions Read carefully the manual Read carefully the manual before installing 1 2 Symbols and warning 1 3 Security System 1 Introduction It is important to establish the MACH...

Страница 4: ...ible clamps It was created to suit various needs both for door gates and sliding gates The design adopted the most advanced techniques to guarantee the utmost immunity vs noises the maximum operating...

Страница 5: ...must be jumpered to the common If the same input has more than one contact NC they are placed in series If they are not used the inputs to the Normally Open NO contacts are left loose If the same inpu...

Страница 6: ...s Neutral 230Vac Ground Phase 230Vac Lamp 230Vac Lamp 230Vac MOT 1 COM MOT 1 OPEN MOT 1 CLOSE MOT 2 COM MOT 2 OPEN MOT 2 CLOSE LSC MOT 2 LSO MOT 2 LSC MOT 1 LSO MOT 1 Photo A only cl START 24 Vac 12 V...

Страница 7: ...Switches motor no 1 LSO M1 15 Input Opening Limit Switches motor no 1 Photocell A 16 Input photocell A working only by closing see chapter 2 3 START 17 Input command bi stable START 24Vac 18 Output f...

Страница 8: ...test on the photocells or for a 24V light you can t use this connection 4 6 Connection of a 24Vdc light with an open and moving gate 28 29 30 31 20 21 If you are expecting to use the test on the photo...

Страница 9: ...3 4 5 Light Group 230 Vac DIP 4 A ON If you are using a piece of stiff wire instead of an an tenna to obtain a 433Mhz frequency you have to cut it off to 17 cm e connect it to the clamp no 25 coaxial...

Страница 10: ...ommand connection on the clamp no 17 connect in parallel The connection of the command for pedestrian opening can be realized on every button or contact as soon as it is type N O normally opened 4 12...

Страница 11: ...EST on the photocells can only ensures the correct working of the automation if said photocells are regularly working The control board will perform a test before every opening In case of malfunction...

Страница 12: ...power supply voltage type N C normally closed POWER SUPPLY RX PHOTOCELL Receiver photocell Clamps contact N C When the control board is powered the led lights that are placed on the inputs are lit up...

Страница 13: ...e output of the terminal board 4 and 5 there is tension at the beginning of the opening till 2 minutes before closing useful to power the courtesy light 5 ON Pre lighting It ables the pre lighting bef...

Страница 14: ...m force for the start and they can reach the planned values This function is not compatible with all gates it should be evaluated according to the installation 5 ON 1 motor It able the use of only one...

Страница 15: ...SC M2 12 Exclusion of the inputs closes limit switches motor no 2 2 ON LSO M2 13 Exclusion of the inputs opens limit switches motor n 2 3 ON LSC M1 14 Exclusion of the inputs of the closing limit swit...

Страница 16: ...t the gate is in CLOSED position Press and keep pressed the codes button 2 Wait for the L E D CODES to start flashing then release it Wait until the reset of the memory 6 1 FULL CANCELLATION of the me...

Страница 17: ...the TIMES button or START if the limit switches are not available The second motor stops wait until the first motor stops END OF LEARNING TIME if the limit switches are available wait until both moto...

Страница 18: ...pause time starts Let the required pause time run 7 Push the TIMES button or START The second motor CLOSES 8 Push the TIMES button or START if the slowing down is activated trimmer see Slow down The...

Страница 19: ...tor no 1 stops The pedestrian door is closed End 4 a If the limit switch is available wait until the motor no 1 pedestrian use stops in its closing Motor no 1 stops by closing limit switches The pedes...

Страница 20: ...rs can be delayed Connect for the TEST 1 When the control is switched OFF put in OFF dip 8 of DIP A 2 Power the control unit and wait the standard flash of the Led 3 Put in ON DIP 8 of DIP A 4 Let the...

Страница 21: ...PEN CLOSE CODES OPEN CLOSE CODES Led indicating the opening is switching on The gate is opening OPEN CLOSE CODES Led opening and closing flashes The gate is open and stop OPEN CLOSE CODES Legend Despl...

Страница 22: ...10 Note START S4XL Technical manual 22...

Страница 23: ...PRODUCT COMPLIES with what is outlined in the European Community directives 2006 95 CE EEC DIRECTIVE 2006 95 ISSUED BY THE EUROPEAN COUNCIL on December 12 2006 harmonizing the legislation of the membe...

Страница 24: ...n est pr sent e sous la seule responsabili du constructeur et si applica ble de son repr sentant autoris Busto Arsizio Va Italia 14 06 2007 ERNESTINO BANDERA Administrateur KONFORMIT TSZERTIFIKAT Der...

Отзывы: