4.9
Connection of arrest devices STOP command
20 21 22 23 24 25
Connection of the
STOP
command
Button: stops and inhibits temporarily the control unit until a
new command.
Switch: keeps the automation blocked until a new retrieval
is ordered.
If the STOP input is NOT
used put the DIP 6 C on ON.
You need to use any kind of button or contact -provided it is type N.O. (normally opened)
to connect the safety devices. If there are several safety devices they have to be connected in series.
23 24 25
4.7
Connection of Courtesy light
3 4 5
Light Group
230 Vac
DIP 4 A - ON
If you are using a piece of stiff wire instead of an an
-
tenna, to obtain a 433Mhz frequency you have to cut
it off to 17 cm e connect it to the clamp no. 25
coaxial antenna
cable sock
4.8
Connection of ANTENNA
12 13 14 15 16 17 18 19 20 21 22 23 24 25
4.10 Connection of the LSO and LSC LIMIT SWITChES
The picture shows the connection of both limit switches.
If the LSO or LSC inputs
aren’t in use, follow the
instructions you find
in chapter n. 4.4
The contacts of the
limit switches must be type N.O
(normally opened)
OPEN
CLOSE
OPEN
CLOSE
MOTOR 1
MOTOR 2
ON
CTS
2
1
4
3
6
5
8
7
10
9
START-S4XL
Technical manual
-9-
ONLY CONNECT ThE ANTENNA AFTER ThE
MEMORIZATION OF ThE RADIO CODES IS DONE!!!