The control board has several micro-switches to activate a lot of functions in order to find suitable solutions for 

the user and to make the installation more safe. 

Functions and adjustments

5.1 

Use of the DIP A

1-OFF 

 2-OFF

Automatic 1

By every order it inverts: 

open and close

It closes automatically at the end of the pause time

1-ON   

2-OFF

condominium

In opening and pause time it doesn’t accept commands. 

it re-closes automatically at the end of the pause time.

1-OFF  

2-ON

Semi automatic

By every command it follows the procedure

open-stop-close-stop-open etc. 

It doesn’t re-close automatically

1-ON   

2-ON

Automatic 2

By every command it follows 

open-stop-close-stop-open etc. 

It recloses automatically at the end of the pause time

3-ON

Reversing

stroke

This function starts a closing thrust at the beginning or 

at the end of the manoeuvre to make easy the work of 

the electronical lock.

4-ON

Courtesy

light

In the output of the terminal board 4 and 5 there is 

tension at the beginning of the opening till 2 minutes 

before closing, useful to power the courtesy light.

5-ON

Pre-lighting

It ables the pre-lighting before each manouevre.

6-ON

Crossing 

detector

As the photocells detect a crossing, the control board 

opens completely then closes but 1 sec. before 

according to the pause time, when the obstacle is gone.

7-ON

Lamp in pause

The lamp is working in the pause time, too.

8-ON

Phototest

Activates the phototest (in presence of TRANSCEIVER, 

see Chap no. 6) 

9-ON

Fix light

The output of the lamp indicating the opening gate is fix 

instead of flashing.

10-ON

Programming

time, advanced

system

It activates the time learning with an advanced system 

(see Chapter no. 5.2)

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

ON

CTS

2

1

4

3

6

5

8

7

10

9

START-S4XL

Technical manual

-13-

Содержание NOLOGO START-S4XL

Страница 1: ...photocell START 24 Vac 24 Vac 12Vac elect lock 12Vac elect lock STOP 26 27 Light Lamp Light Lamp 28 29 Phototest 24 Vac 12 Vac Lamp or courtesy light 230Vac Ground Connection 2 9 10 11 Motor 2 COMMON...

Страница 2: ...hat you contact the competent public agencies the waste collection service or the shop where you purchased the product Small legend OLS Open limit switch CLS Close limit switch START Control to drive...

Страница 3: ...e products 1 1 Safety precautions Read carefully the manual Read carefully the manual before installing 1 2 Symbols and warning 1 3 Security System 1 Introduction It is important to establish the MACH...

Страница 4: ...ible clamps It was created to suit various needs both for door gates and sliding gates The design adopted the most advanced techniques to guarantee the utmost immunity vs noises the maximum operating...

Страница 5: ...must be jumpered to the common If the same input has more than one contact NC they are placed in series If they are not used the inputs to the Normally Open NO contacts are left loose If the same inpu...

Страница 6: ...s Neutral 230Vac Ground Phase 230Vac Lamp 230Vac Lamp 230Vac MOT 1 COM MOT 1 OPEN MOT 1 CLOSE MOT 2 COM MOT 2 OPEN MOT 2 CLOSE LSC MOT 2 LSO MOT 2 LSC MOT 1 LSO MOT 1 Photo A only cl START 24 Vac 12 V...

Страница 7: ...Switches motor no 1 LSO M1 15 Input Opening Limit Switches motor no 1 Photocell A 16 Input photocell A working only by closing see chapter 2 3 START 17 Input command bi stable START 24Vac 18 Output f...

Страница 8: ...test on the photocells or for a 24V light you can t use this connection 4 6 Connection of a 24Vdc light with an open and moving gate 28 29 30 31 20 21 If you are expecting to use the test on the photo...

Страница 9: ...3 4 5 Light Group 230 Vac DIP 4 A ON If you are using a piece of stiff wire instead of an an tenna to obtain a 433Mhz frequency you have to cut it off to 17 cm e connect it to the clamp no 25 coaxial...

Страница 10: ...ommand connection on the clamp no 17 connect in parallel The connection of the command for pedestrian opening can be realized on every button or contact as soon as it is type N O normally opened 4 12...

Страница 11: ...EST on the photocells can only ensures the correct working of the automation if said photocells are regularly working The control board will perform a test before every opening In case of malfunction...

Страница 12: ...power supply voltage type N C normally closed POWER SUPPLY RX PHOTOCELL Receiver photocell Clamps contact N C When the control board is powered the led lights that are placed on the inputs are lit up...

Страница 13: ...e output of the terminal board 4 and 5 there is tension at the beginning of the opening till 2 minutes before closing useful to power the courtesy light 5 ON Pre lighting It ables the pre lighting bef...

Страница 14: ...m force for the start and they can reach the planned values This function is not compatible with all gates it should be evaluated according to the installation 5 ON 1 motor It able the use of only one...

Страница 15: ...SC M2 12 Exclusion of the inputs closes limit switches motor no 2 2 ON LSO M2 13 Exclusion of the inputs opens limit switches motor n 2 3 ON LSC M1 14 Exclusion of the inputs of the closing limit swit...

Страница 16: ...t the gate is in CLOSED position Press and keep pressed the codes button 2 Wait for the L E D CODES to start flashing then release it Wait until the reset of the memory 6 1 FULL CANCELLATION of the me...

Страница 17: ...the TIMES button or START if the limit switches are not available The second motor stops wait until the first motor stops END OF LEARNING TIME if the limit switches are available wait until both moto...

Страница 18: ...pause time starts Let the required pause time run 7 Push the TIMES button or START The second motor CLOSES 8 Push the TIMES button or START if the slowing down is activated trimmer see Slow down The...

Страница 19: ...tor no 1 stops The pedestrian door is closed End 4 a If the limit switch is available wait until the motor no 1 pedestrian use stops in its closing Motor no 1 stops by closing limit switches The pedes...

Страница 20: ...rs can be delayed Connect for the TEST 1 When the control is switched OFF put in OFF dip 8 of DIP A 2 Power the control unit and wait the standard flash of the Led 3 Put in ON DIP 8 of DIP A 4 Let the...

Страница 21: ...PEN CLOSE CODES OPEN CLOSE CODES Led indicating the opening is switching on The gate is opening OPEN CLOSE CODES Led opening and closing flashes The gate is open and stop OPEN CLOSE CODES Legend Despl...

Страница 22: ...10 Note START S4XL Technical manual 22...

Страница 23: ...PRODUCT COMPLIES with what is outlined in the European Community directives 2006 95 CE EEC DIRECTIVE 2006 95 ISSUED BY THE EUROPEAN COUNCIL on December 12 2006 harmonizing the legislation of the membe...

Страница 24: ...n est pr sent e sous la seule responsabili du constructeur et si applica ble de son repr sentant autoris Busto Arsizio Va Italia 14 06 2007 ERNESTINO BANDERA Administrateur KONFORMIT TSZERTIFIKAT Der...

Отзывы: