TIME “START“ IN OPENING
AND CLOSING
TIME “PEDESTRIAN“
IN OPENING AND CLOSING
8 ON
9-10 OFF
10”
(seconds)
6”
(seconds)
9 ON
8-10 OFF
14”
(seconds)
8”
(seconds)
8-9 ON
10 OFF
18”
(seconds)
10”
(seconds)
10 ON
8-9 OFF
22”
(seconds)
12”
(seconds)
8-10 ON
9 OFF
26”
(seconds)
14”
(seconds)
9-10 ON
8 OFF
32”
(seconds)
18”
(seconds)
8-9-10 ON
38”
(seconds)
20”
(seconds)
ON
CTS
2
1
4
3
6
5
8
7
10
9
ON
CTS
2
1
4
3
6
5
8
7
10
9
ON
CTS
2
1
4
3
6
5
8
7
10
9
ON
CTS
2
1
4
3
6
5
8
7
10
9
ON
CTS
2
1
4
3
6
5
8
7
10
9
ON
CTS
2
1
4
3
6
5
8
7
10
9
ON
CTS
2
1
4
3
6
5
8
7
10
9
5.3
Diagram of PEDESTRIAN time and START time
1-ON
LSC M2
12
Exclusion of the inputs closes limit switches motor no.2
2-ON
LSO M2
13
Exclusion of the inputs opens limit switches motor n. 2
3-ON
LSC M1
14
Exclusion of the inputs of the closing limit switches
motor no.1
4-ON
LSO M1
15
Exclusion of the inputs of the opening limit switches
motor no.1
5-ON
Photocell A
16
Exclusion of the input of photocell working in closing.
6-ON
STOP
21
Exclusion of the input stop
7-ON
Photocell B
23
Exclusion input photocell always activated.
8-ON
Radio-
receiver
It activates the radio-receiver
ON
CTS
2
1
4
3
6
5
8
7
ON
CTS
2
1
4
3
6
5
8
7
ON
CTS
2
1
4
3
6
5
8
7
ON
CTS
2
1
4
3
6
5
8
7
ON
CTS
2
1
4
3
6
5
8
7
ON
CTS
2
1
4
3
6
5
8
7
ON
CTS
2
1
4
3
6
5
8
7
5.4
Setting up with DIP C
ON
CTS
2
1
4
3
6
5
8
7
START-S4XL
Technical manual
-15-
Содержание NOLOGO START-S4XL
Страница 22: ...10 Note START S4XL Technical manual 22...