11 Configuring an EtherCAT system with XSOFT-CODESYS
11.2 Configuring the system with XSOFT-CODESYS-3
XN-312-GW-EC gateway 07/20 MN050010-EN
Eaton.com
69
11.2.2 Configuring the EtherCAT master
Follow the steps below to enable communication via EtherCAT:
▶
In the "Devices" pane on the left, select the device you added previously,
e.g., "Device (XC303)".
▶
Right-click on it to open the context menu and select the <Add
device...> option.
The "Add device" dialog box will appear. You can leave the dialog box open.
If the dialog box is not showing a device, make sure that <All manufactur-
ers> is being shown in the "Manufacturer" drop-down menu.
▶
Click on the <EtherCAT | EtherCAT master | Add device> option.
The field bus will be added to the configuration structure.
All the required libraries will be automatically integrated with the EtherCAT
master; for more information, please refer to
EtherCAT communication libraries”, page 77.
Figure 37:
Configuration structure with bus system selected
▶
Click on the "EtherCAT_Master (EtherCAT Master)" node and select the
<Add Device...> option in the context menu.
The "Add device" dialog box will appear if it is not open already.
▶
Select <Field buses | EtherCAT | Slave | Eaton Industries GmbH | Gate-
ways | XN-312-GW-EC | Add Device>.
Содержание XN-312-GW-EC
Страница 1: ...Manual EtherCAT gateway XN 312 GW EC 07 20 MN050010 EN...
Страница 4: ...II...
Страница 12: ...0 About this manual 0 5 Writing conventions 8 XN 312 GW EC gateway 07 20 MN050010 EN Eaton com...
Страница 68: ...10 XN300 Assist 10 1 Firmware update with XN300 Assist 64 XN 312 GW EC gateway 07 20 MN050010 EN Eaton com...
Страница 95: ...12 Sample project 12 7 What will be transferred XN 312 GW EC gateway 07 20 MN050010 EN Eaton com 91...
Страница 102: ...12 Sample project 12 8 Finding XN300 slice module PDOs and SDOs 98 XN 312 GW EC gateway 07 20 MN050010 EN Eaton com...
Страница 130: ...126 XN 312 GW EC gateway 07 20 MN050010 EN Eaton com...