Sonix 2Mx Technical Manual

SONIX 2MX TECHNICAL MANUAL  

TM370 / A  June 2022  www.eaton.com

1  Introduction

These instructions are intended for all users who have to 

install, commission, configure and setup the Sonix 2Mx 

matrix controller.
For this, the manual is action-oriented and explains how 

to achieve a certain objective on a step-by-step basis. It 

is assumed that you have necessary electrical, electronic 

and telecommunications experience to undertake the 

work. If in doubt, please refer to Eaton representative for 

further assistance.

1.1  Eaton quality assurance

Eaton design, manufacture, installs and commission all 

our products to the highest standards of quality. This 

quality process is embraced and adopted throughout the 

group in all areas of our operations. 
This is demonstrated by our compliance and strict 

adherence to ISO 9001, 14001, ATEX, IECEX policies. 
On receipt of the product, ensure that the cartons are 

undamaged and that the contents are all correct and 

complete. 
Should this product reach you in an unsatisfactory 

condition please report this to an Eaton representative  

to enable us to rectify and investigate the fault in a 

speedy manner.

2  About Sonix

The Sonix PA/GA system is designed around a highly 

secure & flexible architecture, that removes the need 

for lengthy engineering cycles, bespoke and costly 

software, custom field engineering or expensive on-site 

support. 
This results in a highly effective and flexible 

communications solution for the next generation.
The Sonix system is rigorously designed for installation 

in both safe area or potentially explosive environments, 

using latest protection philosophies including EExe, d, 

i, m and p to ensure the highest levels of safety whilst 

increasing operational features.
The Sonix PA/GA System is designed to meet and 

surpass the requirements of ATEX, IECEx, DNV, BV, 

ABS, IMO and PFEER, with other regional certifications 

pending.
Please refer to Sonix system technical manual for any 

further information.

3  About the product

3.1  Product description

The Sonix 2Mx matrix controller provides a comprehensive 

yet very flexible control of the Sonix PA/GA system. 

Designed to work with all PA/GA architecture types the 

2Mx is fully configurable to allow customisation and 

modification to the whole Sonix PA/GA system.
Central to the architecture of the Sonix PA/GA system is a 

fully redundant, self-healing data loop connected via RJ45 

style connectors and CAT6A cables. This ensures that 

connectivity of the 2Mx is vastly simplified, plug and play, 

quick to install and reliable.
If a single cable is broken or disconnected, then the PA/

GA system will remain fully operable via the healthy 

side of the loop. All internal cables fed from the 2Mx are 

monitored ensuring that any faults are notified immediately 

to the user via the user display and Sonix Software.
The 2Mx provides simple connectivity and expansion via a 

range of dedicated bus loops on the rear of the unit. These 

colour coded connectors are dedicated to certain features 

such as HMI access panels and amplifier loops. 
If extra equipment is needed within the system, it can 

simple be added to the loop without extensive re-wiring of 

the system.
Via the Sonix software the 2Mx can be configured to 

monitor all aspects of the Sonix PA/GA system. In the 

event of any internal or external field loop faults, early 

warning will be advised via the 2Mx processor and the 

specific PA/GA hardware whilst the audio and data is 

driven both ways on the field loop ensuring no loss of 

broadcast coverage.
All inputs and outputs are always designed to be fail safe 

and reliable to ensure reliable operation. 

The 2Mx matrix controller is a very flexible design allowing for 

custom programming direct to an on-board reprogrammable 
processor for project specific design changes.

3.2  Key features

Sonix 2Mx matrix controller is designed to provide the 

following features:

• 

Central control and monitoring of:

• 

12 zones of address (expandable up to 30 on 

request)

• 

6 independent global alarm tones (expandable up to 

12 on request)

• 

12 independent beacon loops (expandable on 

request)

• 

24 HMI access panels (expandable up to 30 on 

request)

• 

32 amplifiers per system (expandable on request)

• 

Compact 1U, 19” cabinet mounting.

• 

Fully user configurable via Sonix Software.

• 

Configurable to be standalone, A&B or N+1 secure 

architecture

• 

Enhanced with AB+ redundant system improvements

• 

Tick-tone feature for testing and commissioning 

purposes

• 

Beacon test feature for testing and commissioning 

purposes

• 

Provides simple user indication on system status

• 

Comprehensive alarm tone library (custom tones 

available on request)

Содержание SONIX 2Mx

Страница 1: ...Alarms Important Message AUX OPERATIONAL Beacons System Reset Beacon Test Global Ticktone Global Sense Test LOCAL STATUS Matrix HMI Amplifier Beacon I O Power Dist Default Config Bgm 1 2 3 4 5 6 1 2 P...

Страница 2: ...FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF T...

Страница 3: ...feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel SP...

Страница 4: ...Port Indicators 9 5 4 2 Bus connections 10 5 4 2 1 Split loop 10 5 4 3 Audio 10 5 4 4 Global bus 10 6 UNIT OPERATION 11 6 1 Front panel interface 11 6 1 1 Power on reset 11 6 1 2 Power 11 6 1 3 Backgr...

Страница 5: ...g 22 8 7 1 Data monitoring 22 8 7 2 Missing unit monitoring 22 8 7 3 Audio monitoring 22 8 7 4 Unit monitoring 22 8 8 Global Sense test 22 8 9 Access panel timeout 22 8 10 IO Audio timeout 22 9 CUSTOM...

Страница 6: ...N 1 TAP PCB CAT6A CONNECTIONS 19 FIGURE 18 N 1 TAP PCB CONTROL CONNECTIONS 20 FIGURE 19 2MX FAULT TREE 24 LIST OF TABLES TABLE 1 FAULT OUTPUT STATES 9 TABLE 2 DEFAULT CONFIGURATION INPUT STATE 9 TABLE...

Страница 7: ...nfigurable to allow customisation and modification to the whole Sonix PA GA system Central to the architecture of the Sonix PA GA system is a fully redundant self healing data loop connected via RJ45...

Страница 8: ...5 Beacon Bus Beacon bus connections 6 Sync Bus Sync bus connections 7 Power Bus Power bus connections 8 48V Input DC Input connector 9 Fault Output Fault relay output 10 Default Config Communications...

Страница 9: ...T6A The 8off pairs of both 8p8c RJ45 style sockets on the rear of the 2Mx are used to connect and communicate with the other units of a Sonix PA GA system Name Color Connected units Data Audio Amp Gre...

Страница 10: ...5 Split loop bus data flow The only exception to this is the global bus which is not capable of being a loop 5 4 3 Audio Audio is routed in a similar arrangement to the data control flow There are 2...

Страница 11: ...Sonix Hmi 26 see section 8 1 for more details 6 1 4 Local source inputs The local source inputs are comprised of Aux I P and PABX groups Each group has two indicators labelled 1 and 2 The indicators a...

Страница 12: ...ible states Pattern State Both off Error not a valid state Solid Green Healthy no issues Fast Flashing Green Duplicate unit ID seen not affecting system operation but should be corrected as soon as pr...

Страница 13: ...s not available for normal operation without accepting the ping set request first 6 1 13 Internal Fault Buzzer The 2Mx is provided with an internal buzzer that activates each time a new fault occurs T...

Страница 14: ...mplifiers Vw2 Beacon Controller Vw2 Beacon Controller Pbx Fire Gas Ms12 Io Io PABX 2Mx Central Controller 2Mx Central Controller 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli...

Страница 15: ...Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er Vw2 Beacon Controller Vw2 Beacon Controller Controller Vw2 Beacon Controller 2Mx Central Controller 2Mx Central Controller 350 d A...

Страница 16: ...Controller Vw2 Beacon Controller Ms12 A Side Access Panel Access Panel Access Panel Access Panel Access Panel Fire Gas Ms12 Pbx Vw2 Beacon Vw2 Beacon Vw2 Beacon Vw2 Beacon Controller Controller Contr...

Страница 17: ...er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er Vw2 Beacon Controller Vw2 Beacon Controller Controller Vw2 Be...

Страница 18: ...ler Controller Vw2 Beacon Controller Pbx Access Panel Access Panel Access Panel Access Panel Access Panel Fire Gas Pbx Ms12 Vw2 Beacon Vw2 Beacon Vw2 Beacon Vw2 Beacon Controller Controller Controller...

Страница 19: ...ap PCB is required for Amplifier Bus and a second for Beacon Bus if in use The connections for the beacon bus follow an identical pattern to amplifier bus connections shown Unit N Unit 1 Unit 2 Amp Bu...

Страница 20: ...ts of the resolved priority and general operation fault diagnostics The recommended maximum cable run for the sync bus is 100m please discuss with your local Eaton representative on longer distances 7...

Страница 21: ...Software See SAS manual for details 8 2 3 Amplifier faults In a typical PA GA system amplifiers are the most numerous items To aid with issue tracking the extended 2Mx Sync status report into SAS incl...

Страница 22: ...o returning A warning will be raised if a bus stops being a complete loop for audio see 6 1 8 Local Status indicators ote N Hmi Bus connected units access panels are partly wired in spurs they also mo...

Страница 23: ...Alarm Tone that is mixed into the Emergency Speech broadcast is set to approximately 12dB lower than the normal Attenuated Alarm This value can be customised to one of the following 1 1 2 5 4 6 8 5 1...

Страница 24: ...se Fault Split Loop Solid RED Key Flashing RED Flashing GREEN Ms12 Fault Io Audio Input Fault Amplifier Fault Missing Unit Missing Unit Duplicate Unit ID Duplicate Unit ID Duplicate Unit ID Data Routi...

Страница 25: ...red indicator is informing the user that there was an issue on the associated bus but it has been resolved To diagnose the issue users will need to study the log included with SAS assuming that the s...

Страница 26: ...aton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved s...

Отзывы: