Important Safety Instructions

 

DANGER Read all instructions before assembling and using this furnishing - Save these instructions

15�  Ensure that the floor is able to withstand the weight of the 

console when fully loaded�

16�  Ensure the console is plumb and level for proper operation� 

Route all power cords and cabling as instructed, away from 

any possible pinch points or moving parts�

17�  To reduce risk of personal injury and product damage, always 

ensure a sufficient amount of personnel are present when 

unpacking, moving and assembling the console system�

Failure to adhere to these warnings may result in serious 

injury or property damage.

DANGER

Electrical Ratings

Lift motor controller: 

90 – 240V AC, 48Hz – 63Hz (universal)

Console Capacities

Dynamic load capacity of height adjustable lift motors: 

1,000 lb�

Work surface capacity:

 520 lbs�

Base cabinet flush drawer capacity:

  Large drawer: 50 lbs� 

Small drawer: 40 lbs�

Base cabinet roll-out shelf capacity:

 60 lbs�

Monitor pole capacity:

 60 lbs� each

Power distribution strips:

 20 amps 120V AC (2 circuits)

Personal Environment System accessory outlets:

 3 amp ea�

Optional Personal Environment System:

 115V AC, 60Hz

WARNING

Do not apply loads that exceed the capacity of the console� 
The applied load includes any items installed or placed onto the 

console worksurface or into the base cabinet compartments after 

receipt of the console from the carrier� Applied loads include (but 

Console Environment

    

CAUTION

TO ENSURE ADEQUATE AIR FLOW TO COOL STORED 

ELECTRONIC DEVICES, DO NOT LOCATE THE BACK OF THE 

CONSOLE CLOSER THAN 3” TO ANY WALL, OR SIMILAR 

OBSTRUCTION. DO NOT PLACE ANY OBSTRUCTION NEAR 

ANY COOLING PERFORATIONS.

EACH OF THE THREE BASE CABINETS (LH, RH AND CENTER) 

HAS A 650 WATT MAXIMUM COOLING 

CAPACITY� WHEN ADEQUATE AIR FLOW 

IS PROVIDED, THE TEMPERATURE RISE 

WITHIN THE COMPARTMENT WILL BE 

NO GREATER THAN 25 DEGREES (F) 

(14° C)�are not limited to) monitor poles, 

electronic equipment, power distribution 

units, cabling, Personal Environment 

System, and personal items� 

DANGER

DANGER

 – To reduce the risk of electric shock: This console 

includes two power cords� Always fully unplug this console from 

the electrical outlets before cleaning, testing, repairing or moving 

the console�

WARNING

  1�   This console is for commercial use only�
  2�  Unplug from outlet before putting on or taking off parts� NOTE: 

This console includes two power cords�

  3�  Close supervision is necessary when this furnishing is used by, 

or near children, invalids, or disabled persons�

  4�  Use this furnishing only for its intended use as described in 

these instructions� Do not use attachments not recommended 

by the manufacturer�

  5�  Never operate this furnishing if it has a damaged cord or plug, 

if it is not working properly, if it has been dropped or damaged, 

or has become wet� Return the furnishing to a service center 

for examination and repair�

  6� Keep the cord(s) away from heated surfaces�
  7�   Never operate the furnishing with the air openings blocked� 

Keep the air openings free of lint, hair, and the like�

  8� Never drop or insert any object into any opening�
  9� Do not use outdoors�
10�  To disconnect, turn all controls to the off position, then remove 

plugs from outlets�

11�   WARNING: Risk of Electric Shock – Connect this furnishing to 

properly grounded outlets only�  See grounding instructions�

12�  To reduce risk of electrical shock, this furnishing has polarized 

plugs (one blade wider than the other)� These plugs will fit into 

polarized outlets only one way� If a plug does not fit fully into 

the outlet, reverse the plug� If it still does not fit, contact a 

qualified electrician to install the proper outlet� Do not change 

the plug in any way�

13�  DO NOT, UNDER ANY CIRCUMSTANCE, PLACE 

A BODY PART IN THE PATH OF THE 

WORKSURFACE WHILE IT IS BEING 

LOWERED�

DO NOT PLACE ANY OBJECT ON TOP OF THE 

CONSOLE’S SUPPORT BASE THAT COULD INTERFERE WITH 

THE TRAVEL OF THE WORKSURFACE�
This console has an electrically driven adjustable worksurface� In its 

lowest position, the worksurface is very close to the support base 

structure� The console’s lift motors have sensors that will detect 

an obstruction when moving downward� When an obstruction is 

sensed, the worksurface will automatically begin to raise�
14�  Installation and assembly must be performed by qualified 

personnel�

Содержание OnGuard

Страница 1: ...OnGuard Command Console Installation Manual OnGuard Command Console ...

Страница 2: ...s revision history February 2017 First Publication Pub No IB210002EN Sales Representative and Contact Information Contact your Eaton Sales representative using one of the methods below Phone Call us toll free at 800 225 7348 US Only or 508 852 4300 Mail Eaton 160 Gold Star Boulevard Worcester MA 01606 Email InfoESWorcesterMA Eaton com Web Visit us at www eaton com onguard and click on Contact Us S...

Страница 3: ...ng your console Familiarize yourself with the warning symbols that appear throughout this manual Before You Begin Before installing the OnGuard Command Console it is recommended that you do the following SECTION I OnGuard Command Console Installation Manual DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardou...

Страница 4: ...ronment System and personal items DANGER DANGER To reduce the risk of electric shock This console includes two power cords Always fully unplug this console from the electrical outlets before cleaning testing repairing or moving the console WARNING 1 This console is for commercial use only 2 Unplug from outlet before putting on or taking off parts NOTE This console includes two power cords 3 Close ...

Страница 5: ... piece worksurfaces combination wrench PERSONAL ENVIRONMENT SYSTEM Optional Flat blade screw driver or 5 16 nut driver for hose clamps Personalprotectiveequipmentrecommended Eye protection Work gloves Steel toe shoes Monitor Pole Track TechTrack Comfort Edge TechCurb Center Base Cabinet Right Base Cabinet RH Worksurface Support Frame Lift Control Box Leveling Feet Bottom Cable Access Left Base Cab...

Страница 6: ... wood screw Silver 56 pcs F 8 x Phillips head wood screw Black 14 pcs G Tie bolt Silver 6 pcs packaged with worksurface H Non threaded T washer Silver 6 pcs packaged with worksurface I Threaded T nut Silver 6 pcs packaged with worksurface J 10 x 5 8 Phillips flat head screw Silver 4 pcs K 10 Lock Nut Silver 6 pcs L 5 16 Lock Nut Silver 6 pcs M 1 4 Lock Nut Silver 5 pcs N 1 4 Star Washer Silver 5 p...

Страница 7: ... TO A WALL 4 Assemble the left and right base cabinets to center base cabinet with 12 1 4 x 1 2 self threading hex head screws 6 screws for each flank base cabinet 5 Adjust leveling feet to ensure top of base structure is level and aligned NOTICE DO NOT OMIT ANY SCREWS ALL SCREWS ARE REQUIRED TO ENSURE THAT CONSOLE REMAINS STABLE WHEN WORK SURFACE IS ELEVATED TO HIGHEST POSITION ALL LEVELING FEET ...

Страница 8: ...ECTION THEN RE TIGHTEN THE BASE CABINET SCREWS AFTER COMPLETING STEP 2 a Partially insert 2 M6 x 14mm Allen head screws into the innermost side of each outer lift motor Leave screws protruding about 1 4 b Place the support frames into position above the outer lift motors As you lower the frames onto the lift motors ensure that the support frame s screw tabs are first inserted into the center works...

Страница 9: ...pply cable into the lift control box receptacle Loop the power supply cable into the U shaped strain relief slot on control box Then attach control box to front worksurface stiffener with 2 10 x 1 3 4 self threading screws as shown in figure C 1 2 Route the power cord from the control box into the left support frame channel and then through the center worksurface support frame as shown in figure C...

Страница 10: ...he cables into the appropriate numbered receptacles in the control box Motor cable 2 is shown motor cable 3 will follow a similar path through the right support frame 4 Route 2 lift motor cables from the outer lift motors 1 and 4 to the control box plugging the cables into the appropriate numbered receptacles in the control box Motor cable 1 is shown motor cable 4 will follow a similar path throug...

Страница 11: ...er cord into a nearby 120 volt AC outlet 2 The lift motor system is initialized by pressing and holding the down button The motors will automatically lower to their bottom most position if not already there then run upwards approx 3 mm and then down again to their lowest position Only release the down button when the movement has completely stopped 3 If the button is released before the sequence i...

Страница 12: ...trips onto the edges of the rectangular opening in the center worksurface The flexible tabs on the trim strips should be flush with the decorative writing surface of the worksurface 3 Insert the 2 un notched trim strips onto the edges of the rectangular slots in the left and right worksurfaces The flexible tabs on the trim strips should be flush with the decorative writing surface of the worksurfa...

Страница 13: ...NELS TOGETHER BEFORE LIFTING AND POSITIONING THEM 5 Insert 3 tie bolts and 3 non threaded T washers into each outer worksurface 6 Insert plastic splines into the side grooves on each outer worksurface 7 Remove the foam edge protectors then position the worksurface s onto the support frames Ensure that the lift control pad cable sits in the groove in the outer worksurface WARNING AS YOU POSITION TH...

Страница 14: ...uired to bring the components into alignment NOTICE DO NOT TWIST OR FORCE THE WORKSURFACE INTO ALIGN MENT WITH THE SUPPORT STRUCTURE THIS CAN BUILD STRESS INTO THE SYSTEM AND AFFECT THE LIFTING ACTION 10 Attach the worksurface to the support structure with Phillips head wood screws 11 Attach the control pad to the worksurface with 2 8 x Phillips head wood screws Retain the cable in the adjacent sl...

Страница 15: ... the free end of the 10 foot ground wire through the left cable chain and then to the base cabinet s Protective Earth Terminal PET The PET is indicated with a symbol Refer to section V A for instructions on connecting the ground wire to the Protective Earth Terminal PET 3 Pull the lift motor power cord up through the worksurface opening and into the TechCurb Plug the cord into the closest TechCurb...

Страница 16: ...ear corner cover s may be left un installed to enable cable ingress at the corner s 1 Install 2 lower 10 x 3 8 Phillips head self threading screws as shown Leave the screws protruding about 1 16 2 Lower the bottom corner cover onto the two screws engaging the screws it the slots in the cover 3 Secure the cover with two additional top screws 4 Engage the upper corner cover s hooks into the slots an...

Страница 17: ... ships with 4 blank module covers and 1 monitor pole module All of the modules simply snap into the grooves in the center TechTrack trim strips Optional Connectivity Module 2 Connectivity modules are available in 4 3 jack and 8 6 jack widths The module accommodates standard low voltage keystone style snap in connectors not included Optional Personal Environment System Outlet Module See section IV ...

Страница 18: ...o the TechTrack with the 2 threaded studs protruding through the monitor pole module plate The monitor pole module plate is usually located in the center position tabs on plate will register it in position See figure B Refer to the pole attachment steps in the next section To install a monitor pole 1 Assemble the monitor pole base plate onto the pole with 4 Phillips flat head screws included with ...

Страница 19: ...THAT THEYWILL BEAVAILABLETOTHE END USER OFTHE CONSOLE 1 Attach the personal environment system to the underside of the rear worksurface support frame with Tech Curb 4 x 1 2 self threading hex head screws 2 Plug the supplied AC power cord into the unit and then route the cord up into the TechTrack as shown and then into the TechCurb Plug the cord into one of the TechCurb s power strips 3 Run the pe...

Страница 20: ... cap To attach a Trillium style light to the bracket 1 Attach the task light support sleeve and two washers to the bracket with a x 1 Allen head screw and a lock nut 2 The light s support stud can now be inserted into the sleeve Follow the instructions provided with the Trillium light to complete the assembly To attach the bracket to the rear of the monitor pole 1 Remove the monitor pole s top cap...

Страница 21: ...at right and are the only terminals to which the protective earth ground connections shall be attached When grounding the console to the building common ground ing it is essential that the main protective ground is connected and secured to the terminal first with its own star washer and lock nut before any bonding connections are made on top as shown below B B M x 5 N x 5 Hardware required B Plugg...

Страница 22: ...height either in inches or cm The display also shows error codes Adjust the display to show the correct height It may be necessary to adjust the height display after the initial set up of the console Simultaneously press the UP and DOWN arrow buttons or and keep them pressed for 5 seconds This allows the initial height to be re set Until the initial height is re set the display will show three min...

Страница 23: ...s the detection is registered only in the display and no message is sent to the control box E01 The console has an unknown position and needs to be initialized See Section III D E02 Overload upwards has occurred E03 Overload downwards has occurred E16 Illegal keys pressed Other diagnostic error codes may get displayed When calling your customer service representative for technical assistance pleas...

Страница 24: ...ose connections and pinched or frayed wires Laminated Worksurface Care and Cleaning Avoid placing hot items and heat producing appliances on the worksurface When set directly upon the worksurface hot objects can damage the laminated surface To clean the surface use a damp cloth or sponge and a mild soap or detergent Difficult stains such as coffee or tea can be removed using a mild household indus...