11
ONGUARD COMMAND CONSOLE INSTALLATION MANUAL
www.eaton.com/onguard
OnGuard Command Console
Installation Manual
SECTION III - Assembling the Console
5� Plug the lift control pad into the control box, routing the
cord as shown� The control pad can hang freely until the
worksurface is installed� (The control pad may also be
routed to the left side of the console if desired�)
6� Neatly retain exposed cables to front worksurface
stiffener with supplied cable “zip-ties”� Gather any excess
cable length and secure in left and right worksurface
support frames before worksurface is attached�
D. Initialize the Lift Motor Systems
WARNING
BEFORE ENERGIZING OR OPERATING THE LIFT SYSTEM
•
MAKE SURE THAT THE PRECEDING ASSEMBLY STEPS HAVE
BEEN FOLLOWED AND ARE COMPLETED.
•
VERIFY THE CORRECT POSITION OF ALL LIFT MOTOR
CONNECTORS. VERIFY THAT ALL LIFT MOTOR CABLES ARE
PROPERLY SEATED IN THEIR RECEPTACLES.
•
MAKE SURE THAT THE VOLTAGE OF THE CONTROL BOX IS
CORRECT BEFORE THE SYSTEM IS CONNECTED TO THE MAINS.
To initialize the lift motor system:
1� Temporarily plug the power cord into a nearby 120 volt AC
outlet�
2� The lift motor system is initialized by pressing and holding
the down button� The motors will automatically lower to
their bottom most position (if not already there), then run
upwards approx� 3 mm, and then down again to their
lowest position� Only release the down button when the
movement has completely stopped�
3� If the button is released before the sequence is
completed then the initialization is interrupted and must
be started again from the beginning�
4� It is sometimes necessary to press the down button
twice to start the initialization� This is because the system
can be in different modes when the initialization starts�
5� After initialization, press the up button to lift the
worksurface support structure about 18 inches in order to
allow access to the underside of the support structure�
WARNING
•
IF THE CONTROL BOX MAKES UNUSUAL NOISE OR ODORS,
IMMEDIATELY UNPLUG THE UNIT FROM THE AC RECEPTACLE.
•
INSPECT ALL CABLES TO ENSURE THAT THEY ARE NOT
DAMAGED. RECORD ALL ERROR CODES SHOWN.
•
DO NOT PLUG THE UNIT IN AGAIN. CONTACT TECHNICAL
ASSISTANCE FOR HELP USING THE CONTACT INFORMATION
IN SECTION 1 OF THE INSTALLATION GUIDE.
18"
Lift Motor
Cable #4
Lift Motor
Cable #3
Control Pad
Cable
Zip-Tie
C�5
C�6
D�5