SECTION III - Assembling the Console
F. Install the TechCurb
1� Position the three TechCurb sections along the rear edge
of the worksurface, aligning the oval mounting holes
with the pre-drilled holes in the worksurface� Attach the
TechCurbs to the worksurface with (6) ¾" Phillip’s head
wood screws, (2) per section�
The oval mounting holes allow repositioning of the curb
sections to ensure proper alignment with each other�
2� Ground bonding links are pre-attached to each outer
TechCurb, along with one 10 foot ground wire on the left
Techcurb� A short ground wire is also attached to the
center TechCurb lid� Place the loose end of the center
TechCurb ground wire onto the threaded stud and then
secure the ground bonding links to the center TechCurb
with (2) #10 lock nuts, 1 per link�
Route the free end of the 10 foot ground wire through
the left cable chain and then to the base cabinet’s
Protective Earth Terminal (PET)� The PET is indicated
with a symbol� Refer to section V�A for instructions
on connecting the ground wire to the Protective Earth
Terminal (PET)�
3� Pull the lift motor power cord up through the
worksurface opening, and into the TechCurb� Plug the
cord into the closest TechCurb power strip�
4� Route the power strip’s electrical cords down through
the cable chains into the base structure� Ensure that the
power cords are fully inserted into the cable chains�
WARNING
TO ENSURE ELECTRICAL GROUND CONTINUITY THROUGH
THE ENTIRE TECHCURB, THE GROUND CONNECTIONS AS
DESCRIBED ABOVE IN SECTION F.2 MUST BE MADE.
NOTICE
THE TECHCURB LIDS HAVE FRICTION HINGES THAT HOLD
THE LIDS IN A FULLY OPEN POSITION. THE TENSION OF
THE HINGES MAY BE INCREASED BY TURNING THE HINGES’
CENTER ADJUSTMENT SCREWS CLOCKWISE.
E x 6
K x 2
Hardware required
Hardware required
F�1
F�2
F�3
Lift motor
power cord
Power strip
electrical cord
Ground
bonding
link
Center lid
ground
wire
10 foot
ground
wire