25
GREEN MOTION BUILDING INSTALLATION MANUAL
MN191028EN
January 2022 www.eaton.com
00
Title
Figure 13 . J9 layout – Side view
Tag
Description
1
Pin 4
E
2
Pin 19 or 20
GND
3
Edge of PCB
Step 5 .
Connect the terminal E and GND to the shunt trip by passing through the communication cable gland in the
bottom of the EV charger.
Figure 14 . Bottom view of the Green Motion Building EV charger
Tag
Description
1
Communication cable gland
2
Power input
3
Cable output
Step 6 .
Carefully reassemble the platform and close the Green Motion Building EV charger.
3
2
1
1
2
3
If after installation of the shunt trip a contactor failure occurs in the EV charger, the EV charger enters a fault mode. The
LED indicator on the front cover turns red. See Section 9.2. After a few seconds, the emergency output activates the
shunt trip, switching off the circuit breakers.