8-1
Chapter 8
Communication
This chapter describes the communication features of the Eaton Power Xpert 9395C UPS system and provides
information about connecting hardware. For terminal wiring information, see paragraph 3.2.4 and paragraph
4.7. For location of the customer interface panels and terminals, see Figure 4-14 and Figure 4-18 through
Figure 4-21.
8.1
X-Slot Cards
l
Power Xpert
®
Gateway Card - provides a data gateway from the UPS to the Power Xpert software; provides
remote monitoring through a Web browser interface, e-mail, and a network management system using
SNMP; connects to a twisted-pair Ethernet (10/100BaseT) network. Modbus TCP support provides direct
integration of the UPS parameters to a Building Management System (BMS). It has a built-in switching hub
that allows one additional network device to be connected to the network without the requirement of an
additional network drop.
l
Modbus Card - provides direct integration of UPS information (meters and status) to a Building Management
System (BMS) using the Modbus RTU protocol.
l
Relay Interface Card (AS/400) - has isolated dry contact (Form-C) relay outputs for UPS status: Utility failure,
Low battery, UPS alarm/OK, or On bypass when interfacing with IBM AS/400 computers, other relay
connected computers, and industrial applications.
l
Industrial Relay Card (IRC) - indicates the operating status of the UPS system using the customer's
monitoring equipment. The IRC uses four isolated normally-open or normally-closed dry relay contacts to
indicate the UPS status. Online, Bypass, Battery, and Alarm modes can be monitored.
l
Powerware Hot Sync CAN Bridge Card - provides connectivity for operational mode control and metering of
a parallel system at any UPS in the system. In addition, this card can be used to connect optional system
monitoring devices, such as a Remote Monitor Panel II (RMP II), a Relay Interface Module II (RIM II), or a
Supervisory Contact Module II (SCM II) to the UPS.
LAN drops for use with X-Slot connectivity cards must be provided by facility planners or the customer.
For installation and setup of an X-Slot card, contact an Eaton service representative (see page 1-10). Refer to
the manual supplied with the X-Slot card for user instructions.
Figure 8-1. Optional X-Slot Cards
Relay Interface Card
Modbus Card
Hot Sync CAN Bridge
Card
Industrial Relay Card
Power Xpert Gateway Card
Содержание 9395C-1000/1000
Страница 2: ......
Страница 23: ...Section I Installation ...
Страница 24: ......
Страница 93: ...Section II Operation ...
Страница 94: ......
Страница 155: ......
Страница 156: ... P 164000821 1 P 164000821 1 ...