31
most efficient burn.
It is recommended that the firebox is never filled more than
50% to allow room for oxygen.
It is recommended that larger logs are placed in the middle
of the firebox and smaller pieces are placed on the sides
and the top to reduce bridging. Bridging occurs when the
inside of a pile of fuel burns out faster than the surrounded
outer fuel. When this pile collapses it will need a higher
level of oxygen to recover and can result in higher
emissions than in a controlled environment.
Cold-Startup Procedure
For a cold-start, ClearStak recommends that customers fill
the furnace with about two pounds of charcoal per square
foot of the firebox and light it using a propane torch with a
long handle, such as those used in burning weeds to get
the fire started in the most efficient, time saving manner.
Once charcoal is lit and then add wood slowly until the
firebox is about 50% full.
Burn Practices
Warnings
DO NOT
cover air supply or exhaust holes. Any debris
should not restrict air inlet or combustion blower tubes,
stack, and flue baffle at any time during the burn. If
problems continue contact an Earth Outdoor Wood
Furnace distributor or Earth Outdoor.
Always make sure the door provides an air-tight seal when
shut. If door is not air-tight contact an Earth Outdoor Wood
Furnace distributer or Earth Outdoor.
Fuel
Use dry wood. Wood that is wet or damp may cause an
excessive amount of smoke.