28
Catalyst Back Pressure
•
Check catalyst for clogging from objects such as
birds, leaves and bees.
•
Check to see if the heater is performing properly.
•
Check for excess air causing fly ash problems.
•
Check exhaust pipe dimension to insure proper
sizing of pipe.
Balanced System Performance
Every effort has been made to ensure that your heating
furnace has a balanced system performance. This
includes: thermal efficiency, combustion efficiency, and fuel
capacity. It is important to make sure that you do not make
changes to the system without consulting the manufacturer
of the heating furnace. Changes to the blower can
significantly impact combustion efficiency and changes to
the pump can impact thermal efficiency. Changes to the
fuel capacity and delivery can impact both combustion and
thermal efficiency.
Warning Statement and Warning
Symbols
The PCD is very hot during normal operations.
DO NOT
TOUCH
the outside of the PCD or the area above the PCD.
The Pollution Control Device needs to be clean for proper
operation.
DO NOT RUN
the furnace if the catalyst is
OBSTRUCTED
. Please check regularly to insure that the
catalyst is free of obstructions. During initial startup after
a period of dormancy, check the catalyst for obstructions
such as birds, leaves and bees nests.
The ClearStak Model 150 uses 120 V for the operation of
the PCD and the Intelligent Bio-Fuel Controller (IBC).
DO