PCD Wiring Requirements
Two cables connect the PCD to the IBC. The heater cable
is a 14/3 gauge SJO cable, high temperature rated. In
colder climates, an arctic UL approved 14/3 SJTW cable
may be used. The yellow jacketed thermocouple cable is
a 22 gauge shielded wire that is designed for low voltage.
It is the required cable that is provided with the PCD.
PCD External Wiring Requirements for
Switches and Breakers
The catalyst pre-heater is on for approximately one to five
minutes in each call for heat (CFH) cycle of the furnace.
This heater needs 120 VAC to work properly and will draw
approximately 8 to 14 Amps of current. The Earth Outdoor
furnace can have several pumps, fans and an exterior light.
Please ensure that in the event of all devices being turned
on at the same time, the surge and additional load of the
heater will not trip or heat the circuit or switch to an unsafe
level. Please consult an electrician and consult your Earth
Outdoor manual if you do not know how to calculate total
and safe draw.
PCD Ventilation Requirements
The PCD is designed for outdoor use. Heat generated in
the exhaust stream from the combustion of particulates
and gasses needs ambient air to cool and should not be
enclosed. Please ensure that the area around the PCD is
clear and provides an environment for safe operation.
Please consult a certified chimney professional.
Organizations such as the National Fireplace Institute, NFI,
provide a directory of trained technicians.
PCD Voltage and Current Measurement
Proper voltage and current are very important to the