EAE Technology   

  

  

www.eaetechnology.com   

  

  

Page 3 / 21 

 

Product Manual MD

 

100

 

 

 

EAE KNX Motion Detector 

 

 

 

 

 

 

 

MD

 

100

 

 PM R

 

1.0

 

 

 

 

 

Area 

 

64 m

2

 

 

 

 

Angle 

 

360° 

 

 

 

Light level 

 

10 – 1000 lux 

 

Additional channels 

 

 

 

Brightness, presence channel, HVAC 
channel 

 

Parallel operation 

 

 

 

Master/Master, Slave/Master 

 

Operating elements 

 

LED (red) and button 

 

For physical address 

 

Temperature range 

 

Ambient 

 

-5° C   + 45° C 

 

 

 

Storage 

 

-25° C   + 55° C 

 

 

 

Transport 

 

-25° C   + 70° C 

 

Dimensions 

 

 

 

42.5 x 42,5 x 12 mm 

 

Weight 

 

0.06 kg 

 

 

 

Box 

 

Plastic, polycarbonate, colour white 

 

 

 

CE 

 

In accordance with the EMC 
guideline and low voltage 

 

 

 

Application program 

 

Communications objects 

 

Number of addresses(max) 

 

 

 

44 

 

255 

 

 

 

 

 

NOTE: 

Device default physical address is 15.15.255. In order to configure KNX Motion detector, ETS 

application file “.knxprod” is needed. It’s possible to download the file on EAE website. ETS is 
required for programming the device. Parameter settings and related group addresses can be 
changed by ETS. Learn more by reading ETS help file.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detection Range  

Detection range depends on movement types so that these types are divided as follows;  

a)

 

Sitting position in working desk height (0,8m)  

b)

 

Walking straight to the detector   

c)

 

Walking across the detector  

d)

 

Area of the brightness measuring in working desk height (0,8m)  

Содержание MD100

Страница 1: ...EAE KNX Motion Detector Product Manual MD100 Order Number 48018...

Страница 2: ...t 1 General 2 1 1 Technical Data 2 1 2 Operation and Display 4 1 3 Scale Drawings 5 2 Communication Object Information 6 2 3 Communication Object Table 6 2 4 Communication Object Description 8 3 Param...

Страница 3: ...er movement no action Stay on time can be changed the by end user Air conditioning and ventilation systems can be controlled by independent HVAC channel Presence information can be sent to presence mo...

Страница 4: ...guideline and low voltage Application program Communications objects Number of addresses max 44 255 NOTE Device default physical address is 15 15 255 In order to configure KNX Motion detector ETS app...

Страница 5: ...r in meter of the different areas for different installation heights M Detection range 1 2 Operation and Display Figure 1 Surface mounted MD 100 Table 1 Motion M A B C D 5 0m 12 18 3 0 4 0m 10 15 2 3...

Страница 6: ...hnology com Page 5 21 Product Manual MD100 EAE KNX Motion Detector MD100 PM R1 0 Figure 2 Flush mounted MD100 1 KNX connection terminal 2 Programming button 3 Blue movement LED 1 3 Scale Drawings Figu...

Страница 7: ...Flags 0 General In operation DPT 1 002 1 bit CWT 1 General Presence slave 1 DPT 1 001 1 bit CRW 2 General Presence slave 2 DPT 1 001 1 bit CRW 3 General Presence slave 3 DPT 1 001 1 bit CRW 4 General...

Страница 8: ...24 Group 2 output Dimming level DPT 5 001 8 bit CRT 25 Group 2 input Switch light DPT 1 001 1 bit CW 26 Group 2 input Dimming level DPT 5 001 8 bit CW 27 Group 2 input Dimming light DPT 3 007 4 bit C...

Страница 9: ...tion objects by master sensor Slave sensors send the value 1 when movement is present otherwise send value 0 These values are processed in OR gate by master sensor If the output value is 1 master sens...

Страница 10: ...ue Sensor will calculate the calibration factor according to new lux value automatically Subsequent detections will be calculated with new calibration factor 12 Constant Light External Brightness DPT...

Страница 11: ...to output object at detected movement and stays ON until t adjusted time runs out Current Lighting stay ON time can be read from the object or a new Lighting stay ON time can be written to the object...

Страница 12: ...ng a telegram through this object has an alterable behaviour according to Light level control parameter in the Constant light level parameter window Disable constant light and dim It remains disabled...

Страница 13: ...re enables the constant light control and switches the lighting OFF Don t disable and no action No action receiving a telegram through Group 1 input object 3 Parameters Parameters chapter describes E...

Страница 14: ...ble HVAC no yes Parameter enables brightness parameters and objects Overwrite settings for download yes no This parameter is used to decide whether settings stated below are overwritten or not by down...

Страница 15: ...ter detecting first movement Detector waits for selected number of movements during Presence switch ON delay time in order to send that the presence information is ON Presence stay ON time sec 1 10 25...

Страница 16: ...d with the value 0 and re enabled with value 1 Behaviour disable lighting no action Light ON Light OFF This parameter is used for selecting whether to send a telegram from the presence output object b...

Страница 17: ...ration factor This parameter is used select calibration method of the brightness sensor inside the detector There are two options in order to calibrate the brightness sensor Via object Calibration val...

Страница 18: ...rightness on off control Lighting groups are only controlled by switch object according to set point value If measured brightness value is greater than the set point value switch object is set to the...

Страница 19: ...point value 100 95 90 etc Transmit next dimming value after 0 5s 1s 2s 3s 5s This parameter is used to specify the time interval between two sending dimming value After sending a dimming value 60 nex...

Страница 20: ...f lighting Automatically ON and OFF Lighting group is controlled automatically by detector according to presence information If person is present in the room ON command is sent to the lighting group i...

Страница 21: ...value OFF and enabled with the value ON Behaviour disable lighting no action Light ON Light OFF This parameter is used for selecting whether a telegram is sent to lighting group before disabling ligh...

Страница 22: ...d Stay ON time objects are not visible Disable light level control no ON for disabling OFF for enabling OFF for disabling ON for enabling This parameter determines the value type for disabling enablin...

Страница 23: ...etechnology com Page 22 21 Product Manual MD100 EAE KNX Presence Detector MD100 PM R1 0 Light ON After enabling the HVAC output it is set to the value ON Light OFF After enabling the HVAC output it is...

Отзывы: