_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No. IS 2463-P      Issue E          19-03-10                               

Sheet 6 of 6 

 
 
 

Unit No. 2

+

-

Sounder

PCB

 +   -   

S2

  

S3

Unit No. 1

Beacon 
PCB

 

+   - 

-

+

-

 

+   - 

Beacon 
PCB +

 

+   - 

Beacon 
PCB

 +   -   

S2

  

S3

Sounder

PCB

 +   -   

S2

  

S3

Sounder

PCB

-

+

Unit No. 3

S2

S3

Unit No. 2

L

C

N

L

N

L  N   C

 

S2

 

S3

Sounder

PCB

Unit No. 1

L   N 

Beacon 
PCB

L   N 

Beacon 
PCB

L   N 

Beacon 
PCB

L  N   C

 

S2

 

S3

Sounder

PCB

L  N   C

 

S2

 

S3

Sounder

PCB

Unit No. 3

 

Unit No. 2

C

N

S3

S2

L

Sounder

PCB

Unit No. 1

L  N   C S2

 

S3

Beacon 

PCB

 L   N 

L
N

 L   N 

Beacon 
PCB

L
N

Beacon 
PCB

 L   N 

Sounder

PCB

L  N   C S2

 

S3

L  N   C S2

 

S3

L
N

Sounder

PCB

Unit No. 3

BExDCS110-05D DC Combined Sounder Unit 

Beacon and Sounder Wired for Simultaneous Operation 

BExDCS110-05D AC Combined Sounder Unit 

Beacon and Sounder Wired for Independent Operation 

BExDCS110-05D AC Combined Sounder Unit 

Beacon and Sounder Wired for Simultaneous Operation 

NOTE 

Either the L or the N wire may be 
made common to both the sounder 
and the beacon to reduce the 
number of cores in the cable. 

Содержание BE DCS110-05D Series

Страница 1: ...O NOT OPEN WHEN AN EXPLOSIVE GAS DUST ATMOSPHERE IS PESENT COVER BOLTS CLASS A4 80 USE HEAT RESISTING CABLES AND CABLEGLANDS Rated 110 C AT AMB TEMPERATURES OVER 40 C Year of Construction Serial No i...

Страница 2: ...installation On completion of the cable wiring installation the flameproof joints should be inspected to ensure that they are clean and that they have not been damaged during installation Also check t...

Страница 3: ...glands approved for Ex d applications can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN60079 14 2008 I...

Страница 4: ...operate the sounder on stage one simply connect the supply voltage to the normal supply terminals ve and ve for DC units L and N for AC units The operation of the second and third stages is different...

Страница 5: ...ency Description 1 2 3 4 5 Stage 2 Stage 3 1 Continuous 1000Hz Toxic gas alarm 0 0 0 0 0 Tone 31 Tone 11 2 Alternating 800 1000Hz at 0 25s intervals 1 0 0 0 0 Tone 17 Tone 5 3 Slow Whoop 500 1200Hz at...

Страница 6: ...r PCB Unit No 1 L N Beacon PCB L N Beacon PCB L N Beacon PCB L N C S2 S3 Sounder PCB L N C S2 S3 Sounder PCB Unit No 3 Unit No 2 C N S3 S2 L Sounder PCB Unit No 1 L N C S2 S3 Beacon PCB L N L N L N Be...

Страница 7: ...ccleston Chester CH4 9JN UK Quality Assurance Notification SIRA 05 ATEX M342 Provisions fulfilled by the equipment ll2 G Ex d llB T4 ll 2 D Ex tD A21 IPGX T100 C or T115 C Standards applied EN 60079 0...

Отзывы: