PULL DOWN MENUS
4-5
August 2000
Part No. 001-2001-200
Figure 4-9 OUTPUT ALARMS
Alarm Description
This is a text string (up to 15 characters) to
describe the alarm. This test string is sent via Morse
code if the alarm input is programmed with a Tx ID
and an output is selected in the cross reference menu
(see Figure 4-10).
Transmit ID
Each of the 8-alarm outputs can be assigned a
Group ID from 1-225. The default setting is 0 (zero)
for disabled. This Group ID and the Repeater number
identify an alarm that is active. This ID can be pro-
grammed into a transceiver so that when the alarm is
active, the alarm description is received in Morse
code.
Alarm Transmit Rate
This sets the time interval for transmitting the
alarm message in Morse code. If more than one alarm
is active, this is the inter-alarm time.
Cross Reference
The cross reference screen selects the output
alarm that is activated by each input alarm. There are
up to 48 alarms (0-47), 8 external input alarms and 40
internal alarms (see Table 1-2). There are eight output
alarms. An alarm condition on any input can cause an
output alarm. This screen configures which input
alarm activates an output alarm.
NOTE: More than one alarm condition can have the
same output alarm (see Figure 4-10).
Description
Spacebar
Output Alarm Configuration
Output Type Selection
Tx ID
Alarm 1 Output Type: Active Open
Alarm 2 Output Type: Active Open
Alarm 3 Output Type: Active Open
Alarm Tx Rate:
0
Press F2 to Accept
DOOR OPEN
FUEL 1/2
FUEL 1/4
RF HALF POWER
Alarm 4 Output Type: Active Closed
15
120
120
0
Figure 4-10 ALARM CROSS REFERENCE
4.3.4 REPEATER TYPE
This screen (see Figure 4-11) selects the repeater
type (LTR signaling protocol and features):
Repeater Type
VHF
Channel Bandwidth 12.5/25 kHz
Frequency Range
132-150/150-178 MHz
Figure 4-11 REPEATER TYPE
4.3.5 DELETE REPEATER
Figure 4-12 DELETE REPEATER
Select which Output Alarm is activated by each Input Alarm.
8. None
24. None
32. None
40. None
5. None
6. None
7. None
9. None
10. None
11. None
12. None
13. None
14. None
15. None
17. None
18. None
19. None
20. None
21. None
22. None
23. None
25. None
26. None
27. None
28. None
29. None
30. None
31. None
34. None
35. None
36. None
37. None
38. None
39. None
41. None
42. None
43. None
44. None
45. None
46. None
47. None
Alarm Cross Reference Selection
Press F2 to Accept
0. None
1. 1
2. 1
3. 2
4. 3
16. None
33. 4
Select Rptr To Delete
Rptr 1
Содержание 242-20X1-213
Страница 2: ...1 2 October 1995 Part No 001 2008 202 ...
Страница 14: ...TABLE OF CONTENTS CONT 10 ...
Страница 24: ...INTRODUCTION AND OPERATION 1 10 August 2000 Part No 001 2001 200 ...
Страница 94: ...CIRCUIT DESCRIPTION 6 44 August 2000 Part No 001 2001 200 ...
Страница 118: ...ALIGNMENT AND TEST PROCEDURES 7 20 August 2000 Part No 001 2001 200 ...
Страница 126: ...SERVICING 8 8 August 2000 Part No 001 2001 200 ...
Страница 160: ...PARTS LIST 9 34 August 2000 Part No 001 2001 200 ...
Страница 197: ......
Страница 198: ...Part Number 001 2001 200 8 00mwp Printed in U S A ...