ALIGNMENT AND TEST PROCEDURES
7-16
August 2000
Part No. 001-2001-200
7.4.8 REPEATER OPERATION
New HSDB Test
1. On the MPC, switch settings for RS-485 operation
are shown in Figure 7-10.
Figure 7-10 NEW HSDB SWITCH SETTINGS
2. Verify that the repeater is programmed for "Stand
Alone" mode in Setup Parameters-F4 (see Section
4.3.1).
3. The repeater is now in Normal Operation mode.
Verify by the MPC front panel indicators that no
HSDB alarms have occurred (Alarm Number 10)
see Table 1-2.
Handshake Test
1. Program an LTR portable or mobile for the follow-
ing parameters.
Home Repeater - Same as repeater number.
Area - Same as repeater’s area bit.
Home Repeater’s Channel Number -
Sameas repeater’s channel number.
Group 1 Encode/Decode - 1
2. The repeater is now in Normal Operation mode.
3. Key the radio several times on the programmed
System/Group. Access should occur every time.
(Proper Tx/Rx antenna connections are assumed.)
Alarm Test
1. The repeater is now in Normal Operation mode.
2. Verify by the MPC front panel indicators that no
alarms have occurred (see Table 1-2).
Figure 7-11 J2 TERMINAL BLOCK
ON
ON
S3
S2
2
1
8
7
6
5
4
3
2
1
4
3
2
1
33
34
J2
TXS+
TXS-
RXS-
RXS+
RXA+
RXA-
TXA+
TXA-
Содержание 242-20X1-213
Страница 2: ...1 2 October 1995 Part No 001 2008 202 ...
Страница 14: ...TABLE OF CONTENTS CONT 10 ...
Страница 24: ...INTRODUCTION AND OPERATION 1 10 August 2000 Part No 001 2001 200 ...
Страница 94: ...CIRCUIT DESCRIPTION 6 44 August 2000 Part No 001 2001 200 ...
Страница 118: ...ALIGNMENT AND TEST PROCEDURES 7 20 August 2000 Part No 001 2001 200 ...
Страница 126: ...SERVICING 8 8 August 2000 Part No 001 2001 200 ...
Страница 160: ...PARTS LIST 9 34 August 2000 Part No 001 2001 200 ...
Страница 197: ......
Страница 198: ...Part Number 001 2001 200 8 00mwp Printed in U S A ...