P/N: 975389
|
Rev: current
|
ECO: xxxxx
www.dynisco.com
From lab to production,
providing a window into the process
-30-
•
Insert the four M5x20 BHCS screws supplied (Dynisco part number S0911) thru the
drill holes in the back of the box so the screw line up with the T-nuts installed
earlier in item 3.
•
Secure the HMI box to item 3 by tightening the four M5 screws.
•
Close the HMI box by putting the cover panel back on and screw the 4 original cover
screws back in:
be careful to not pinch any wiring when closing the cover
4.5
Install Vortex coolers into RSU & RCU (option)
4.5.1
Installing RSU Vortex cooler
•
Install small 90degree pressure fitting into Vortex cooler port using teflon tape
•
Remove plastic plug from RSU 90 degree cooler port (installed in back plate of RSU
containing the box receptacles)
•
Thread Vortex cooler into 90 degree port until fully seated
Содержание ViscoIndicator
Страница 20: ...P N 975389 Rev current ECO xxxxx www dynisco com From lab to production providing a window into the process 20 ...
Страница 28: ...P N 975389 Rev current ECO xxxxx www dynisco com From lab to production providing a window into the process 28 ...
Страница 38: ...P N 975389 Rev current ECO xxxxx www dynisco com From lab to production providing a window into the process 38 ...